When your microbore applications need the performance and flexibility of ternary solvent selection and the productivity and performance of x2 dual LC, the x2 Dual Micro is the system of choice. The throughput of your best microbore separations can be increased up to 100% with the tandem or parallel configurations. On-line sample preparation with high efficiency columns creates many options for reduced interferences and short analysis cycles. For LC/MS, these benefits translate into improved utilization of the MS and improved performance of fast, microbore LC/MS separations. The x2 Dual Micro System can be configured and reconfigured to always meet the changing demands of your laboratory.
- Maximized eluent options for 2-D separations
- Microbore optimized system delay volume
- Precise, accurate autosampling from well plates and microvials
- Chromeleon® software wizards guide setup of dual configurations
| x2 Dual Micro |
|---|
| Maximum system pressure | 41 MPa (6000 psi) |
| PUMP |
|---|
| Recommended pump | DPG-3600BM |
| Flow rate range (settable) | 50–2500 µL/min (1–2500 µL/min) |
| Flow accuracy | ±0.5% |
| Flow precision | <0.05% RSD or <0.01 min SD, whichever is greater |
| Pressure range | 2–50 MPa (290–7250 psi) |
| No of eluent lines | 6 (2 × 3) |
| Gradient delay volume | 220 µL |
| Solvent degassing | External (optional) |
| AUTOSAMPLER |
|---|
| Recommended sampler | WPS-3000TRS |
| Injection volume range (recommended) | 0.01–100 µL (1–100 µL) Optional: 0.2–25 µL, 1.5–250 µL, 1.5–500 µL |
| Injection volume accuracy | ±0.5% at 50 µL and 90 µL |
| Injection volume precision | <0.25% RSD at 5 µL (typically <0.15%RSD), caffeine in water |
| Linearity | Corr. coeff. >0.9999, RSD <0.5% at 5–90 µL, caffeine in water |
| Carry over | <0.004% for caffeine with external wash |
| Injection cycle time | <15 s for 5 µL |
| Sample thermostating | 4–45 °C, at 22 °C below ambient |
| COLUMN COMPARTMENT |
|---|
| Recommeneded column compartment | TCC-3000SD |
| No. of switching valves | Optional, up to 2 |
| Recommended eluent pre-heater volume | 2 µL (0.005" i.d.) |
| Temperature range | 5 °C to 80 °C |
| Temperature accuracy | ±0.5 °C |
| Temperature stability/precision | ±0.1 °C |
| DETECTOR |
|---|
| Recommended detector | VWD-3100 |
| Detector type | Variable Wavelength |
| Number of channels | 1 |
| Wavelength range | 190–900 nm |
| Max. data collection rate | 100 Hz |
| Recommended flow cell | Semi-micro flow cell, 2.5 µL, SST |
| Noise | <±3.5 µAU at 254 nm |
| Drift | <0.1 mAU/h |
Performance Examples
UltiMate® 3000 HPLC systems deliver improvements in HPLC performance while ensuring easy, reliable operation.The UltiMate 3000 series operates over a wide range of flow rates, including preparative, analytical, micro, and nano/capillary scales, supporting applications such as discovery processes, quality control, and advanced research like proteomics.
Rapid Separation LC offers the highest flow-pressure range to meet your chromatographic goals whatever the may be. Developing separations in seconds rather than in minutes requires a system that provides excellent precision, speed, and performance. Use the RSLC Method Transfer Calculator for quick and easy conversion of conventional HPLC to UHPLC methods.
| Hardware |
| SRD-3600 UltiMate 3000 Integrated Solvent and Degasser Rack, 6 Channels |
5035.9230 |
| DGP-3600M UltiMate 3000 Dual-Gradient Micro Pump System |
5035.0050 |
| WPS-3000TSL UltiMate 3000 Thermostatted Analytical Sampler |
5822.0020 |
| TCC-3000SD Thermostatted Column Compartment |
5730.0010 |
| VWD-3400RS - UltiMate 3000 Rapid Separation Four Channel Variable Wavelength Detector (Without Flow Cell) |
5074.0010 |
| Accessories |
| Sample loop, 25 μL, for UltiMate 3000 WPS-3000SL Analytical and WPS-3000RS Autosampler Series, until S/N 8049346
|
6820.2415 |
| Pod for 2-Position 10-Port HP Valve, SST Variant, Pressure < 413 bar (6,000 psi) |
6722.9023 |
| Semi-micro Flow Cell for VWD-3000 Series, SST, 2.5 µL Volume, 7 mm Pathlength |
6074.0360 |
| Viper UHPLC Fingertight Fitting and Capillary Kit for Online SPE on UltiMate 3000 x2 Dual RSLC Systems |
6040.2801 |
| Viper UHPLC Fingertight Fitting and Capillary Kit for Tandem Operation on UltiMate 3000 x2 Dual RSLC Systems |
6040.2803 |
| Viper UHPLC Fingertight Fitting and Capillary Kit for Application Switching on UltiMate 3000 x2 Dual RSLC Systems |
6040.2805 |
| Viper UHPLC Fingertight Fitting and Capillary Kit for Automated Method Scouting on UltiMate 3000 Quaternary RSLC Systems |
6040.2807 |
| Viper UHPLC Fingertight Fitting and Capillary Kit for Parallel Setup on UltiMate 3000 x2 Dual RSLC Systems |
6040.2809 |
| Pod for 2-Position 6-Port HP Valve, SST Variant, Pressure < 413 bar (6000 psi) |
6722.9013 |
| Pod for 6-Position 7-Port HP Valve, Titanium Variant, 10-32 Fittings, Pressure < 413 bar/6000 psi
|
6722.9035 |