The Corona™ ultra™ RS detector brings charged aerosol detection to UHPLC. The Corona ultra RS detector delivers the speed and resolution of UHPLC to the analysis of any nonvolatile or semi-volatile analyte, with or without a chromophore, for performance no other detector can provide.
Charged Aerosol Detector Demo
- Nanogram to picogram sensitivity
- Response independent of chemical structure
- Wide dynamic range
- Ease of use
- Compatibility with UHPLC/RSLC
- Easily switch between parallel detectors (e.g. MS)
- Ability to change from volatile to non-volatile mobile phases without removing detector from the system
- Easily integrates with any HPLC system
The Corona ultra RS detector has the flexibility to operate with standard HPLC or UHPLC systems, with no modifications necessary. From analytical development to production, the Corona ultra RS detector brings a high level of reliability to any analysis.
Note: A nitrogen generator (70-6003) is recommended for use with the Corona ultra RS detector.
| Specifications for Corona ultra RS Detector |
|---|
| Operating Mode | Charged Aerosol Detection |
| Mobile Phase Flow Rate | 0.2 mL/min to 2 mL/min |
| Wettable Surfaces | 316 stainless steel, Nitronic® 60 stainless steel, Valcon H, Valcon E, PEEK™, and Teflon® |
| Full Scale Output Range | 1 pA to 500 pA in 1-2-5 sequence |
| Filter Time Constants | Selectable in numerical sequence (1-2-3 etc. sequence) |
| Noise Specification | <750 fA peak to peak (20% methanol/80% water) |
| Signal Output | 0 V to 1 V DC |
| Output Resolution | 0.12 µV at 1 V full scale |
| Maximum Output Data | 200 Hz |
| Display | LCD |
| Nebulizer Settable Temperature Range | 5°C to 35°C – Factory set at 25 °C |
| Temperature Stability | < ± 0.5° C |
| Integrated Switching Valve | 6-port, 2-position, driver controlled |
| Flow Diversion System | Sensor and firmware for waste bottle overfill prevention |
| Warm-Up Time | < 30 min (typically) |
| Optional Flow Splitter | Adjustable split from 1:1 to 20:1 |
| Interface | Integrated touch screen |
| Power Requirements | 100-120 V, 60 Hz; 230-240 V, 50 Hz; 100 VA |
| Gas | Air or Nitrogen and must not contain volatile hydrocarbons (e.g. compressor oil), particulates and water vapor |
| Input Gas Pressure | 60 psi (4.14 bar) |
| Operating Gas Flow | Approximately 4 L/min |
| Dimensions and Weight | 43 × 36 × 20 cm (17 × 14 × 8 in); 12.3 kg (27 lbs) |
| Laboratory Equipment Certifications | |
| USA | UL 61010A-1, 1st Edition |
| Canada | CSA Standard C22.2 No. 1010.1-92 |
| European Union | EN 61326:1997 + A1:1998 EN 61010-1 (2001-02) |
| FCC | Part 15 Subpart B Class A |
The Corona® ultra™ comes complete with accessories.
| Hardware |
| Corona Ultra RS - UltiMate 3000 Charged Aerosol Detector: Speed and resolution of UHPLC to the analysis of any nonvolatile or semi-volatile analyte, with or without a chromophore. Easy to incorporate into the work flow. |
70-9406 |
| Accessories |
| Nitrogen Generator for Corona CAD detector, benchtop. Provides high purity Nitrogen (+99%) from 60-125 psig with maximum flow of 4 L/min. Installation kit included. Requires compressed air inlet (95-145 psig) |
70-6003 |