Autosampler Column Compartment
The UltiMate® 3000 Autosampler Column Compartment ACC-3000(T) provides a cost-effective solution for conventional LC and UHPLC applications at up to 62 MPa (9000 psi) operating pressure. It integrates an autosampler and column oven in a single module and offers performance and flexibility that exceed most analytical method requirements. In addition, it reduces height and cost of your LC system.
- Cost effective injection and column compartment module for conventional HPLC and UHPLC
- Pulled-loop injection principle (full- and partial-loop injections possible)
- Wide injection volume ranges from 1–10 μL in partial-loop and 20 μL in full-loop mode, or 10–100 μL and 200 μL, respectively
- Low sample carryover
- Patented temperature control to protect thermally sensitive samples
- Accurate and precise column temperature control for reliable chromatographic results
- Built-in eluent preheating for increased chromatographic reliability at high temperatures
- Easy front access to all fluidic components
- Trouble-free operation due to minimized number of wear parts
The UltiMate 3000 Autosampler Column Compartment is recommended for research and other analytical laboratories operating in a cost-sensitive environment. It is available in variants with (ACC-3000T) and without sample thermostatting (ACC-3000) and is an essential part of the UltiMate 3000 Basic Automated System.
| Autosampler Column Compartment Specifications |
|---|
| Sample capacity | 3 × 40 vials (1.8 mL) or 3 × 72 vials (1.2 mL) or 3 × 22 vials (4 mL) or 3 × 10 vials (10 mL) plus 3 × 5 vials (10 mL) |
| Injection technique | Pulled loop, with programmable needle wash |
| Injection methods | Pulled loop, using full loop or partial loop fill |
| Injection volume precision | <0.25% RSD in full loop mode (20 µL loop) Typically <0.3% RSD in partial loop mode at 5 µL (20 µL loop) |
| Linearity | Corr. coeff. >0.9995, RSD <1% in partial loop mode for 1–10 µL (20 µL loop); Corr. coeff. >0.9995, RSD <0.5% in partial loop mode for 10–100 µL (200 µL loop) |
| Carry over | <0.02% with caffeine |
| Injection cycle time | Typically <45 seconds with 5 µL injection |
| Optional sample thermostatting | 8–40 °C, min. 15 °C below ambient |
| Column temperature range: | 5 °C above ambient to 50 °C |
| Maximum operating pressure | 62 MPa (9000 psi) |
| Dimensions (h x w x d) | 40 × 42 × 51 cm (16 × 16.5 × 20 in.) |
| PC Connection | USB; USB hub with 3 sockets integrated |
| Additional specifications | Please see data sheet |
| Hardware |
| ACC-3000 UltiMate 3000 Autosampler with Integrated Column Compartment |
5830.0010 |
| ACC-3000T UltiMate 3000 Thermostatted Autosampler with Integrated Column Compartment |
5830.0020 |
| Accessories |
| ACC-3000 Sample Loop, 50 µL |
6830.2442 |
| Syringe, 1000 µL, for WPS-3000 and WPS-3000 SL Series |
6822.0005 |
| Sample Tray for 72 Cylindrical 0.3 mL Vials, WPS-3000 (PL/SL/RS) and ACC-3000 Series |
6820.4091 |
| Sample tray for 40 conical vials, 1.1 mL vials, all WPS-3000 variants |
6820.4087 |
| Sample Tray for 72 Cylindrical Mini Vials 1.2 mL, WPS-3000 and WPS-3000 SL Series |
6820.4090 |
| Vial Tray Compl, WPS |
6820.4070 |
| Sample Tray for 22 Cylindrical Vials 4 mL, WPS-3000 and WPS-3000 SL Series |
6820.4084 |
| Sample Tray for 10 Cylindrical Vials 10 mL, WPS-3000 and WPS-3000 SL Series |
6820.4086 |
| Transparent Front Cover for WPS-3000PL, WPS-3000SL and ACC-3000 Series |
6820.1419 |