Home >
Dionex Products >
Ion Chromatography >
IC and Reagent-Free IC Modules >
IC and RFIC Detectors >
ICS Series Photodiode Array Detector
ICS Series Photodiode Array Detector
The ICS-5000 Series Photodiode Array Detector maximizes your optical absorbance information by providing full UV-Vis spectra in high resolution along with an ultra-quiet optical bench for excellent detection performance.
- 1024-element photodiode array for optimum wavelength resolution
- Broad wavelength range from 190 to 800 nm
- Deuterium and tungsten lamps for low noise and high intensity over the full spectral range
- Full control and data collection through Chromeleon software with 3-D option
- USB-based digital data collection for simple installation
- Four analog outputs to support alternate data collection
- Built-in holmium oxide filter for easy verification of wavelength accuracy
- Low baseline drift for excellent reliability and reproducibility
- Front access to prealigned cells and lamps that simplifies routine maintenance
- Five front-panel LEDs that clearly indicate detector status
- Limited stand-alone operation without software control, allowing simplified troubleshooting or temporary operation without a computer
- Simple software panels for operation in multiwavelength mode
| ICS Series PDA Photodiode Array Detector Specifications |
|---|
| Noise | ±10 µAU at 254 nm (flowing water, 2-s rise time) ±15 µAU at 520 nm (flowing water, 2-s rise time) |
| Drift | <500 µAU/h |
| Wavelength accuracy | ±1 nm, self-calibration with deuterium lines, verification with built-in holmium oxide filter |
| Resolution | 1 nm |
| Linearity | >2 AU |
| Photodiode array | 1024 |
| Pixel resolution | 0.7 nm |
| Optical resolution | 1.0 nm |
| Lamps | Tungsten and deuterium |
| Analog outputs | Four, 0–3 AU, 1000 mV range |
| Flow cell materials | PEEK, fused silica, SST |
| Path length | 10 mm |
| Cell volume | 13 µL |
| Flow cell pressure limit | <2 MPa (300 psi) PEEK <3 MPa (500 psi) SST |
Dimensions (h x w x d) | 17.4 × 44.4 × 50.3 cm (6.8 × 17.5 × 20 in.) |
| Physical specifications | Power Requirements: 90–265 V ac, 47–63 Hz (autosensing) Operating Temp. Range: 4–40 °C (40–104 °F) Operating Humidity Range: 5–95% relative, noncondensing |
| Hardware |
| PDA Photodiode Array Detector |
064447 |
| Absorbance Cell, PEEK, 13 µL |
056346 |
| Absorbance Cell, Semi Micro (PEEK), 3 µL, 9 mm Path Length |
064169 |
| Absorbance Cell, Semi Prep (PEEK), 0.7 µL, 0.4 mm Path Length |
064167 |
| Absorbance Cell, SST |
056126 |
| Absorbance Cell, Semi Micro (SST), 3 µL, 9 mm Path Length |
064168 |
| Software |
| Chromeleon option for PDA Full spectrum Data Acquisition |
060728 |
- Chromatography Data Systems