Thermo Scientific™

Acclaim™ Organic Acid HPLC Columns

Catalog number: 062902
Thermo Scientific™

Acclaim™ Organic Acid HPLC Columns

Catalog number: 062902

For unparalleled performance in separating hydrophilic, aliphatic, and aromatic organic acids use Thermo Scientific™ Acclaim™ Organic Acid LC Columns. These high-efficiency, reversed-phase silica columns are compatible with 100% aqueous mobile phases and have excellent hydrolytic stability at low pHs for excellent selectivity in the separation of organic acids. Achieve high-resolution separations with fast run times and minimal sample preparation.

 
Catalog Number
062902
Unit Size
Each
Particle Size
5 μm
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,086.85
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)4 mm
Flow Rate0.6 to 1.5 mL/min
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size5 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
5 μm
Diameter (Metric)
4 mm
Length (Metric)
150 mm
Price (USD)
Price: 937.26
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)4 mm
Flow Rate0.6 to 1.5 mL/min
Length (Metric)150 mm
Max. Pressure4000 psi (275 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size5 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
Catalog Number
Unit Size
Pack of 2
Particle Size
5 μm
Diameter (Metric)
3 mm
Length (Metric)
10 mm
Price (USD)
Price: 248.89
Your price:
Full specifications
Quantity
Column FormatGuard Cartridge, 2 Pk.
Diameter (Metric)3 mm
Length (Metric)10 mm
Particle Size5 μm
pH2 to 8
Pore Size120 Å
Surface Area300 m²/g
Temperature60°C
USP TypeN/A
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSilica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeGuard Cartridge
Unit SizePack of 2
Catalog Number
Unit Size
Pack of 2
Particle Size
5 μm
Diameter (Metric)
4 mm
Length (Metric)
10 mm
Price (USD)
Price: 207.22
Your price:
Full specifications
Quantity
Column FormatGuard Cartridge, 2 Pk.
Diameter (Metric)4 mm
Length (Metric)10 mm
Max. Pressure6000 psi (415 bar)
Particle Size5 μm
pH2 to 8
Pore Size120 Å
Surface Area300 m²/g
Temperature60°C
USP TypeN/A
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSilica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeGuard Cartridge
Unit SizePack of 2
Catalog Number
Unit Size
Each
Particle Size
3 μm
Diameter (Metric)
3 mm
Length (Metric)
150 mm
Price (USD)
Price: 987.51
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)3 mm
Flow Rate0.3 to 0.8 mL/min
Length (Metric)150 mm
Max. Pressure3000 psi (207 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size3 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
Catalog Number
Unit Size
Each
Particle Size
3 μm
Diameter (Metric)
2.1 mm
Length (Metric)
150 mm
Price (USD)
Price: 987.51
Your price:
Full specifications
Quantity
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.2 to 0.5 mL/min
Length (Metric)150 mm
Max. Pressure3000 psi (207 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size3 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
Showing 6 of 6
Catalog NumberSpecificationsUnit SizeParticle SizeDiameter (Metric)Length (Metric)Price (USD)Quantity
062902Full specifications
Each5 μm4 mm250 mm
Price: 1,086.85
Your price:
Column FormatAnalytical Column
Diameter (Metric)4 mm
Flow Rate0.6 to 1.5 mL/min
Length (Metric)250 mm
Max. Pressure4000 psi (275 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size5 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
062903Full specifications
Each5 μm4 mm150 mm
Price: 937.26
Your price:
Column FormatAnalytical Column
Diameter (Metric)4 mm
Flow Rate0.6 to 1.5 mL/min
Length (Metric)150 mm
Max. Pressure4000 psi (275 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size5 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
071987Full specifications
Pack of 25 μm3 mm10 mm
Price: 248.89
Your price:
Column FormatGuard Cartridge, 2 Pk.
Diameter (Metric)3 mm
Length (Metric)10 mm
Particle Size5 μm
pH2 to 8
Pore Size120 Å
Surface Area300 m²/g
Temperature60°C
USP TypeN/A
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSilica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeGuard Cartridge
Unit SizePack of 2
069700Full specifications
Pack of 25 μm4 mm10 mm
Price: 207.22
Your price:
Column FormatGuard Cartridge, 2 Pk.
Diameter (Metric)4 mm
Length (Metric)10 mm
Max. Pressure6000 psi (415 bar)
Particle Size5 μm
pH2 to 8
Pore Size120 Å
Surface Area300 m²/g
Temperature60°C
USP TypeN/A
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSilica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeGuard Cartridge
Unit SizePack of 2
070086Full specifications
Each3 μm3 mm150 mm
Price: 987.51
Your price:
Column FormatAnalytical Column
Diameter (Metric)3 mm
Flow Rate0.3 to 0.8 mL/min
Length (Metric)150 mm
Max. Pressure3000 psi (207 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size3 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
070087Full specifications
Each 3 μm2.1 mm150 mm
Price: 987.51
Your price:
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.2 to 0.5 mL/min
Length (Metric)150 mm
Max. Pressure3000 psi (207 bar) aqueous, 2000 psi (140 bar) organic
Metal Impurity<10.0 ppm Total Metal, <3.0 ppm Individual Metal
Particle ShapeSpherical
Particle Size3 μm
Particle Size Distribution<1.3
pH2 to 8
Pore Size120 Å
Pore Volume1 mL/g
Surface Area300 m²/g
Surface Coverage2.7 mmol/m²
Temperature60°C
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load17%
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeAnalytical Column
Unit SizeEach
Showing 6 of 6
High-Efficiency, High-Throughput Organic Acid Analysis
  • Ideal selectivity for small hydrophilic organic acids, C1 to C7 aliphatic acids and hydrophilic aromatic acids
  • Excellent column efficiency and peak shapes for organic acids
  • Hydrolytic stability at low-pH conditions for optimum reversed-phase retention of organic acids
  • Use-tested to guarantee consistent hydrophilic organic acid separations
  • Packed in metal-free PEEK column bodies to eliminate unwanted interaction between the analytes and the column body
  • Available in 3.0 and 5.0μm particle sizes and 2.1, 3.0, and 4.0mm diameters, with 150 and 250mm lengths

Recommended for analysis and quality testing of foods, beverages, pharmaceuticals, chemical intermediates and environmental samples.

About the Family of Acclaim Specialty HPLC Columns

Acclaim specialty columns have been developed, manufactured and tested to meet the separation needs of specific applications. These columns are based on novel and unique chemistries and provide superior resolution with ease-of-use.

  • Use-tested to guarantee consistent separations
  • Ideal selectivity for separating specific target analytes
  • Excellent peak shapes
  • Performance tested to ensure high quality and reliability for specific chromatographic separations
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text