Thermo Scientific™

Dionex™ IonPac™ CS5A IC Columns

Catalog number: 052576
Thermo Scientific™

Dionex™ IonPac™ CS5A IC Columns

Catalog number: 052576
Determine common transition and lanthanide metals simultaneously in less than 11 minutes with the Thermo Scientific™ Dionex™ IonPac™ CS5A column. This is a high-resolution column designed for accurate determination of transition and lanthanide metals in a variety of sample matrices. The Dionex IonPac CS5A column, in combination with postcolumn derivitization for visible detection at 530nm, provides a sensitive and selective method for transition metal analysis.
 
Catalog Number
052576
Unit Size
Each 1
Column Type
Analytical Column
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,670.00
Your price:
Full specifications
Quantity
Column ConstructionPEEK with Internal Style 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
Column TypeAnalytical Column
Crosslinking10% DVB
Column CapacityCation 5 μeq, Anion 10 μeq
Column ChemistryAcidic
Flow Rate0.3 to 0.5 mL/min.
For Use With (Application)Ion Exchange
For Use With (Equipment)CSRS
Ion Exchange GroupCation: Sulfonic Acid / Anion: Quaternary Ammonium
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityTypical HPLC Solvents Up to 50%
Particle Size9 μm
Stationary PhaseIonPac CS5A
FormatMicrobore
Latex CrosslinkingCation: 10% / Anion: 2%
Resin CompositionBead Diameter: 9 μm; Crosslinking: 55% DVB
SolventsTypical HPLC Solvents to 50%
Length (Metric)250 mm
Diameter (Metric) LatexCation: 140 nm / Anion: 76 nm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
046100TS
also known as 046100
Unit Size
Each 1
Column Type
Analytical Column
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,600.00
Your price:
Full specifications
Quantity
Column ConstructionPEEK with Internal Style 1-32 threaded ferrule-style end fittings. All components are nonmetallic.
Column TypeAnalytical Column
Crosslinking10% DVB
Column CapacityCation 20 μeq, Anion 40 μeq
Column ChemistryAcidic
Flow Rate1.2 to 2.0 mL/min.
For Use With (Application)Ion Exchange
For Use With (Equipment)CSRS
Ion Exchange GroupCation: Sulfonic Acid / Anion: Quaternary Ammonium
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityTypical HPLC Solvents Up to 50%
Particle Size9 μm
Stationary PhaseIonPac CS5A
FormatStandard Bore
Latex CrosslinkingCation: 10% / Anion: 2%
Resin CompositionBead diameter: 9 μm; Crosslinking: 55%
SolventsTypical HPLC solvents to 50%
Length (Metric)250 mm
Diameter (Metric) LatexCation: 140 nm / Anion: 76 nm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Your price:
Full specifications
Quantity
Column TypeGuard Column
For Use With (Application)Analysis of Transition and Lanthanide Metals
For Use With (Equipment)Analysis of Transition and Lanthanide Metal
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityUp to 50% Common HPLC Solvents
Particle Size9 μm
Stationary PhaseIonPac CG5A
FormatStandard Bore
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Online price: 465.80
Your price:
Full specifications
Quantity
Column TypeGuard Column
For Use With (Application)Analysis of Transition and Lanthanide Metals
For Use With (Equipment)Analysis of Transition and Lanthanide Metal
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityUp to 50% Common HPLC Solvents
Particle Size9 μm
Stationary PhaseIonPac CG5A
FormatMicrobore
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeColumn TypeDiameter (Metric)Length (Metric)Price (USD)Quantity
052576Full specifications
Each 1Analytical Column2 mm250 mm
Price: 1,670.00
Your price:
Column ConstructionPEEK with Internal Style 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
Column TypeAnalytical Column
Crosslinking10% DVB
Column CapacityCation 5 μeq, Anion 10 μeq
Column ChemistryAcidic
Flow Rate0.3 to 0.5 mL/min.
For Use With (Application)Ion Exchange
For Use With (Equipment)CSRS
Ion Exchange GroupCation: Sulfonic Acid / Anion: Quaternary Ammonium
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityTypical HPLC Solvents Up to 50%
Particle Size9 μm
Stationary PhaseIonPac CS5A
FormatMicrobore
Latex CrosslinkingCation: 10% / Anion: 2%
Resin CompositionBead Diameter: 9 μm; Crosslinking: 55% DVB
SolventsTypical HPLC Solvents to 50%
Length (Metric)250 mm
Diameter (Metric) LatexCation: 140 nm / Anion: 76 nm
Diameter (Metric)2 mm
Unit SizeEach 1
046100TS
also known as 046100
Full specifications
Each 1Analytical Column4 mm250 mm
Price: 1,600.00
Your price:
Column ConstructionPEEK with Internal Style 1-32 threaded ferrule-style end fittings. All components are nonmetallic.
Column TypeAnalytical Column
Crosslinking10% DVB
Column CapacityCation 20 μeq, Anion 40 μeq
Column ChemistryAcidic
Flow Rate1.2 to 2.0 mL/min.
For Use With (Application)Ion Exchange
For Use With (Equipment)CSRS
Ion Exchange GroupCation: Sulfonic Acid / Anion: Quaternary Ammonium
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityTypical HPLC Solvents Up to 50%
Particle Size9 μm
Stationary PhaseIonPac CS5A
FormatStandard Bore
Latex CrosslinkingCation: 10% / Anion: 2%
Resin CompositionBead diameter: 9 μm; Crosslinking: 55%
SolventsTypical HPLC solvents to 50%
Length (Metric)250 mm
Diameter (Metric) LatexCation: 140 nm / Anion: 76 nm
Diameter (Metric)4 mm
Unit SizeEach 1
046104Full specifications
Each 1Guard Column4 mm50 mm
Price: 548.00
Your price:
Column TypeGuard Column
For Use With (Application)Analysis of Transition and Lanthanide Metals
For Use With (Equipment)Analysis of Transition and Lanthanide Metal
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityUp to 50% Common HPLC Solvents
Particle Size9 μm
Stationary PhaseIonPac CG5A
FormatStandard Bore
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
052836Full specifications
Each 1Guard Column2 mm50 mm
Price: 548.00
Online price: 465.80
Your price:
Column TypeGuard Column
For Use With (Application)Analysis of Transition and Lanthanide Metals
For Use With (Equipment)Analysis of Transition and Lanthanide Metal
Max. Pressure2500 psi (170 bar)
Solvent CompatibilityUp to 50% Common HPLC Solvents
Particle Size9 μm
Stationary PhaseIonPac CG5A
FormatMicrobore
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Showing 4 of 4
Rapid, Routine Analysis of Transition and Lanthanide Metals in Diverse Samples
  • Sensitive and selective analysis of transition metals in combination with postcolumn derivitization and visible detection at 530 nm.
  • Unique bifunctional resin rapidly provides excellent selectivity for simultaneous determination of common transition and lanthanide metals.
  • Transition metals as well as aluminum are detected following complexation with 4-(2-pyridylazo) resorcinol (PAR).
  • Compatible with up to 50% organic solvents to enhance analyte solubility, modify column selectivity, and simplify column clean-up
Two Eluent Concentrates for Maximum Flexibility
  • Ready-to-dilute, high-purity eluent concentrates are available to easily optimize the Dionex IonPac CS5A column selectivity.
  • The MetPac PDCA eluent uses pyridine-2,6-dicarboxylic acid as a strong complexing agent that separates the metal complexes by anion exchange. The PDCA eluent is best suited for the separation of iron (II) and iron (III), copper, nickel, zinc, cobalt, cadmium, and manganese.
  • The MetPac Oxalic Acid eluent uses oxalic acid as a moderate-strength complexing agent to separate metals by a mixed mode mechanism. The oxalate eluent separates lead, copper, cadmium, cobalt, zinc, and nickel.
Multiple Formats Available for Application Flexibility
  • 4 x 250mm, 2 x 250mm analytical columns
  • 4 x 50mm, 2 x 50mm guard columns
  • Longer 250mm columns facilitate higher resolution separations of more complex sample matrices
  • Smaller I.D. columns provide higher mass sensitivity, eluent and reagent conservation and lower operating costs
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References