For Fast Gradient Separation of Inorganic Anions in High-Purity Water Matrices
The Thermo Scientific* Dionex* IonPac* AS17-C column is a low-capacity column for fast, gradient separation of inorganic anions. Its key application is the determination of common inorganic anions in high-purity water matrices. The Dionex IonPac AS17-C provides low sulfate blanks and fast equilibration time. It is recommended for use with RFIC* systems using the Eluent Generator for electrolytic eluent generation. Use the Dionex ASRS* 300 Anion Self-Regenerating Suppressor with the Dionex IonPac AS17-C column.
- Recommended replacement for all Dionex IonPac AS17 anion applications
- Optimized for common inorganic anions in simple sample matrices
- Fast gradient separation of inorganic anions in high-purity water matrices
- Fast, gradient separation of sulfur species including sulfite, sulfate, and thiosulfate
- Compatible with RFIC systems and the Eluent Generator for automatic eluent generation
Note: The Dionex IonPac AS18 column is the recommended hydroxide-selective column for determination of common anions in diverse sample matrices.
| IonPac AS17-C Anion-Exchange Column Specifications |
|---|
| Dimensions: | IonPac AS17-C Analytical Column: 2 x 250 mm and 4 x 250 mm IonPac AG17-C Guard Column: 2 x 50 mm and 4 x 50 mm |
| Maximum Operating Pressure: | 4000 psi |
| Mobile Phase Compatibility: | pH 0-14; 0-100% HPLC solvents |
| Substrate Characteristics: | Bead Diameter: 10.5 µm Crosslinking (%DVB): 55% |
| Latex Characteristics: | Functional Group: Alkanol quaternary ammonium ion Latex Crosslinking: 6% Latex Diameter: 75 nm Hydrophobicity: Low |
| Capacity: | 7.5 µeq (2 x 250 mm analytical column) 1.5 µeq (2 x 50 mm guard column) 30 µeq (4 x 250 mm analytical column) 6 µeq (4 x 50 mm guard column) |
| Column Construction: | PEEK with 10-32 threaded ferrule style end fittings. All components are nonmetallic. |

Determination of sulfur species in a simulated industrial wastewater sample using an IonPac AS17-C Column.

Determination of anions and organic acids in high-purity water using a large loop injection with potassium hydroxide gradient on a 4 mm IonPac AS17-C column.

Determination of anionic additives in toothpaste on an IonPac AS17-C column using a potassium hydroxide gradient delivered by an Eluent Generator.

Anion separation including oxyhalides on an IonPac AS17-C column using a potassium hydroxide gradient delivered by an Eluent Generator.
| Analytical Columns |
| IonPac AS17-C Analytical Column (4 x 250 mm) |
066294 |
| IonPac AS17-C Analytical Column (2 x 250 mm) |
066296 |
| Guard Columns |
| IonPac AS17-C Guard Column (4 x 50 mm) |
066295 |
| IonPac AG17-C Guard Column (2 x 50 mm) |
066297 |