Thermo Scientific™

Dionex™ IonPac™ CS16 IC Columns

Catalog number: 057574
Thermo Scientific™

Dionex™ IonPac™ CS16 IC Columns

Catalog number: 057574
Determine disparate concentration ratios of adjacent eluting cations such as sodium and ammonium in diverse sample matrices using the Thermo Scientific™ Dionex™ IonPac™ CS16 Capillary, Analytical & Guard Column. Sample matrices include environmental waters; power plant waters treated with ammonium, morpholine or ethanolamine; chemical additives; chemical process solutions; scrubber solutions; plating baths; and industrial solvents. The Dionex IonPac CS16 column is designed and recommended for use in most Thermo Scientific™ Dionex™ IonPac™ CS15 column applications due to its larger linear working range.
 
Catalog Number
057574
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
5 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Your price:
Availability
-
Full specifications
Quantity
Column TypeGuard Column
Column Capacity1700 μeq
Column ChemistryAcidic
For Use With (Application)Cation Exchange
For Use With (Equipment)IonPac CS16 Analytical Column
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CG16
FormatStandard Bore
Length (Metric)50 mm
Diameter (Metric)5 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Analytical Column
Diameter (Metric)
3 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,670.00
Your price:
Availability
-
Full specifications
Quantity
Column TypeAnalytical Column
Crosslinking55% DVB
Column Capacity3000 μeq
Column ChemistryAcidic
Flow Rate0.36 to 0.72 mL/min.
For Use With (Application)Cation Exchange
For Use With (Equipment)Eluent Generator
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CS16
FormatMicrobore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Solvents0 to 100% HPLC Acetonitrile. Alcohols Should be Avoided.
Length (Metric)250 mm
Diameter (Metric)3 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Capillary Separator
Diameter (Metric)
0.5 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,670.00
Online price: 1,419.50
Your price:
Availability
-
Full specifications
Quantity
Column TypeCapillary Separator
Crosslinking55% DVB
DescriptionCS16; 0.5 x 250 mm
Column Capacity84 μeq
Column ChemistryAcidic
Flow Rate0.01 to 0.02 mL/min.
For Use With (Application)Cation Exchange
For Use With (Equipment)Eluent Generator
HydrophobicityMedium
Max. Pressure5000 psi (345 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CS16
FormatCapillary
Packing MaterialEthylvinylbenzene/Divinylbenzene
Solvents0 to 100% HPLC Acetonitrile. Alcohols Should be Avoided.
Length (Metric)250 mm
Diameter (Metric)0.5 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
0.5 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Online price: 465.80
Your price:
Availability
-
Full specifications
Quantity
Column TypeGuard Column
Column Capacity17 μeq
Column ChemistryAcidic
For Use With (Application)Cation Exchange
For Use With (Equipment)CCES 300
HydrophobicityMedium
Max. Pressure5000 psi (345 bar)
Solvent CompatibilityAcidic Eluents, 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CG16
FormatCapillary
Length (Metric)50 mm
Diameter (Metric)0.5 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Analytical Column
Diameter (Metric)
5 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,670.00
Your price:
Availability
-
Full specifications
Quantity
Column TypeAnalytical Column
Crosslinking55% DVB
Column Capacity8400 μeq
Column ChemistryAcidic
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Cation Exchange
For Use With (Equipment)Eluent Generator
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CS16
FormatStandard Bore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Solvents0 to 100% HPLC Acetonitrile. Alcohols Should be Avoided.
Length (Metric)250 mm
Diameter (Metric)5 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
3 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Your price:
Availability
-
Full specifications
Quantity
Column TypeGuard Column
Column Capacity600 μeq
Column ChemistryAcidic
For Use With (Application)Cation Exchange
For Use With (Equipment)IonPac CS16 Analytical Column
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CG16
FormatMicrobore
Length (Metric)50 mm
Diameter (Metric)3 mm
Unit SizeEach 1
Showing 6 of 6
Catalog NumberSpecificationsUnit SizeColumn TypeDiameter (Metric)Length (Metric)Price (USD)AvailabilityQuantity
057574Full specifications
Each 1Guard Column5 mm50 mm
Price: 548.00
Your price:
-
Column TypeGuard Column
Column Capacity1700 μeq
Column ChemistryAcidic
For Use With (Application)Cation Exchange
For Use With (Equipment)IonPac CS16 Analytical Column
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CG16
FormatStandard Bore
Length (Metric)50 mm
Diameter (Metric)5 mm
Unit SizeEach 1
059596Full specifications
Each 1Analytical Column3 mm250 mm
Price: 1,670.00
Your price:
-
Column TypeAnalytical Column
Crosslinking55% DVB
Column Capacity3000 μeq
Column ChemistryAcidic
Flow Rate0.36 to 0.72 mL/min.
For Use With (Application)Cation Exchange
For Use With (Equipment)Eluent Generator
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CS16
FormatMicrobore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Solvents0 to 100% HPLC Acetonitrile. Alcohols Should be Avoided.
Length (Metric)250 mm
Diameter (Metric)3 mm
Unit SizeEach 1
075401Full specifications
Each 1Capillary Separator0.5 mm250 mm
Price: 1,670.00
Online price: 1,419.50
Your price:
-
Column TypeCapillary Separator
Crosslinking55% DVB
DescriptionCS16; 0.5 x 250 mm
Column Capacity84 μeq
Column ChemistryAcidic
Flow Rate0.01 to 0.02 mL/min.
For Use With (Application)Cation Exchange
For Use With (Equipment)Eluent Generator
HydrophobicityMedium
Max. Pressure5000 psi (345 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CS16
FormatCapillary
Packing MaterialEthylvinylbenzene/Divinylbenzene
Solvents0 to 100% HPLC Acetonitrile. Alcohols Should be Avoided.
Length (Metric)250 mm
Diameter (Metric)0.5 mm
Unit SizeEach 1
075402Full specifications
Each 1Guard Column0.5 mm50 mm
Price: 548.00
Online price: 465.80
Your price:
-
Column TypeGuard Column
Column Capacity17 μeq
Column ChemistryAcidic
For Use With (Application)Cation Exchange
For Use With (Equipment)CCES 300
HydrophobicityMedium
Max. Pressure5000 psi (345 bar)
Solvent CompatibilityAcidic Eluents, 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CG16
FormatCapillary
Length (Metric)50 mm
Diameter (Metric)0.5 mm
Unit SizeEach 1
079805Full specifications
Each 1Analytical Column5 mm250 mm
Price: 1,670.00
Your price:
-
Column TypeAnalytical Column
Crosslinking55% DVB
Column Capacity8400 μeq
Column ChemistryAcidic
Flow Rate1.0 to 2.0 mL/min.
For Use With (Application)Cation Exchange
For Use With (Equipment)Eluent Generator
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CS16
FormatStandard Bore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Solvents0 to 100% HPLC Acetonitrile. Alcohols Should be Avoided.
Length (Metric)250 mm
Diameter (Metric)5 mm
Unit SizeEach 1
079931Full specifications
Each 1Guard Column3 mm50 mm
Price: 548.00
Your price:
-
Column TypeGuard Column
Column Capacity600 μeq
Column ChemistryAcidic
For Use With (Application)Cation Exchange
For Use With (Equipment)IonPac CS16 Analytical Column
HydrophobicityMedium
Max. Pressure4000 psi (275 bar)
Solvent CompatibilityAcidic Eluents, 0 to 100% HPLC Acetonitrile, Alcohols Should be Avoided
Particle Size5.5 μm
Stationary PhaseIonPac CG16
FormatMicrobore
Length (Metric)50 mm
Diameter (Metric)3 mm
Unit SizeEach 1
Showing 6 of 6
Superior Performance When Determining Disparate Ratios of Sodium and Ammonium
  • Optimized for the determination of disparate concentration ratios of adjacent eluting cations such as sodium and ammonium in diverse sample matrices.
  • Determination of short-chained alkylamines and alkanolamines in the presence of lithium, sodium, ammonium, potassium, magnesium, and calcium in complex sample matrices.
  • Resolution of sodium and ammonium ratios up to 10,000:1 in less than 20 minutes using an isocratic acid eluent
  • Resolution of sodium and ammonium ratios up to 20,000:1 using a gradient methanesulfonic acid (MSA) eluent
  • High capacity column for improved sample loadability and peak resolution
  • Maximum peak efficiencies at an optimized operating temperature of 40˚C
  • Best carboxylate-functionalized column for samples with low pH
  • Compatible with organic solvents, excluding alcohols, to enhance analyte solubility, modify column selectivity, and facilitate effective column clean-up

Reduce Operating Costs With Lower Eluent Requirements

The Dionex IonPac CS16 capillary column provides the same performance as the standard bore and microbore Dionex IonPac CS16 columns because it is packed with the same material. Operating costs are reduced because the capillary system operates at only 1% of the eluent flow rate of the standard bore system, requiring less eluent and producing less waste.


Multiple Formats Available for Application Flexibility
  • 5x250mm, 2x250mm analytical columns
  • 5x50mm, 2x50mm guard columns
  • 0.5x250mm capillary columnm, 0.5x50mm capillary guard column
  • Longer 250mm columns facilitate higher resolution separations of more complex sample matrices
  • Smaller i.d. columns provide higher mass sensitivity, eluent and reagent conservation and lower operating costs.
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text