Thermo Scientific™

Dionex™ IonPac™ AS4A-SC IC Columns

Catalog number: 043174
Thermo Scientific™

Dionex™ IonPac™ AS4A-SC IC Columns

Catalog number: 043174
For fast, isocratic separation of inorganic anions in environmental waters, the Thermo Scientific™ Dionex™ IonPac™ AS4A-SC column was the preferred column for many years. It was first introduced in 1984 and is the specified column in U.S. EPA Method 300.0 (A). However, the advanced, high-capacity Dionex IonPac AS22 Carbonate Eluent Anion-Exchange column is recommended for fast analysis of inorganic anions in diverse matrices when using carbonate eluents.
 
Catalog Number
043174
Unit Size
Each 1
Column Type
Analytical Column
Diameter (Metric)
4 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,670.00
Your price:
Full specifications
Quantity
Column ConstructionPEEK
Column TypeAnalytical Column
Crosslinking0.5% DVB
Certifications/ComplianceMeets or Exceeds US EPA Method 300.0 (A) Performance Requirements
Column Capacity20 μeq
Column ChemistryCarbonate/Bicarbonate
Flow Rate2.0 to 3.0 mL/min.
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)ASRS Anion Self-Regenerating Suppressor
HydrophobicityMedium-Low
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AS4A-SC
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)250 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
4 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Your price:
Full specifications
Quantity
Column TypeGuard Column
Certifications/ComplianceU.S. EPA Method 300.0 (A)
Column Capacity4 μeq
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)4 mm Concentrator, Single Piston Pump such as the DQP or DXP Pump
HydrophobicityMedium-Low
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AG4A-SC
FormatStandard Bore
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Analytical Column
Diameter (Metric)
2 mm
Length (Metric)
250 mm
Price (USD)
Price: 1,670.00
Your price:
Full specifications
Quantity
Column ConstructionPEEK
Column TypeAnalytical Column
Crosslinking0.5% DVB
Certifications/ComplianceMeets or Exceeds US EPA Method 300.0 (A) Performance Requirements
Column Capacity5 μeq
Column ChemistryCarbonate/Bicarbonate
Flow Rate0.5 to 0.75 mL/min.
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)ASRS Anion Self-Regenerating Suppressor
HydrophobicityMedium-Low
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AS4A-SC
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Catalog Number
Unit Size
Each 1
Column Type
Guard Column
Diameter (Metric)
2 mm
Length (Metric)
50 mm
Price (USD)
Price: 548.00
Your price:
Full specifications
Quantity
Column TypeGuard Column
Certifications/ComplianceU.S. EPA Method 300.0 (A)
Column Capacity1 μeq
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)4 mm Concentrator, Single Piston Pump such as the DQP or DXP Pump
HydrophobicityMedium-Low
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AG4A-SC
FormatMicrobore
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeColumn TypeDiameter (Metric)Length (Metric)Price (USD)Quantity
043174Full specifications
Each 1Analytical Column4 mm250 mm
Price: 1,670.00
Your price:
Column ConstructionPEEK
Column TypeAnalytical Column
Crosslinking0.5% DVB
Certifications/ComplianceMeets or Exceeds US EPA Method 300.0 (A) Performance Requirements
Column Capacity20 μeq
Column ChemistryCarbonate/Bicarbonate
Flow Rate2.0 to 3.0 mL/min.
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)ASRS Anion Self-Regenerating Suppressor
HydrophobicityMedium-Low
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AS4A-SC
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)250 mm
Diameter (Metric)4 mm
Unit SizeEach 1
043175Full specifications
Each 1Guard Column4 mm50 mm
Price: 548.00
Your price:
Column TypeGuard Column
Certifications/ComplianceU.S. EPA Method 300.0 (A)
Column Capacity4 μeq
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)4 mm Concentrator, Single Piston Pump such as the DQP or DXP Pump
HydrophobicityMedium-Low
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AG4A-SC
FormatStandard Bore
Length (Metric)50 mm
Diameter (Metric)4 mm
Unit SizeEach 1
043125Full specifications
Each 1Analytical Column2 mm250 mm
Price: 1,670.00
Your price:
Column ConstructionPEEK
Column TypeAnalytical Column
Crosslinking0.5% DVB
Certifications/ComplianceMeets or Exceeds US EPA Method 300.0 (A) Performance Requirements
Column Capacity5 μeq
Column ChemistryCarbonate/Bicarbonate
Flow Rate0.5 to 0.75 mL/min.
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)ASRS Anion Self-Regenerating Suppressor
HydrophobicityMedium-Low
Ion Exchange GroupAlkanol Quaternary Ammonium Ion
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AS4A-SC
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach 1
043126Full specifications
Each 1Guard Column2 mm50 mm
Price: 548.00
Your price:
Column TypeGuard Column
Certifications/ComplianceU.S. EPA Method 300.0 (A)
Column Capacity1 μeq
For Use With (Application)Separation of Inorganic Anions, Anion Exchange
For Use With (Equipment)4 mm Concentrator, Single Piston Pump such as the DQP or DXP Pump
HydrophobicityMedium-Low
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% HPLC Solvents
Particle Size13 μm
Stationary PhaseIonPac AG4A-SC
FormatMicrobore
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach 1
Showing 4 of 4
Fast Isocratic Separation of Inorganic Anions in Simple Matrices
  • Compliance monitoring of common anions in drinking water as specified in U.S. EPA Methods 300.0 (A)
  • Separation of common inorganic anions in 10 minutes in water, food and beverages, and other diverse sample matrices
  • Compatible with sodium tetraborate gradient to optimize difficult separations
  • Solvent compatibility for easy column cleanup after the analysis of samples with hydrophobic components
Multiple Formats Available for Application Flexibility
  • 4×250mm, 2x250mm analytical columns
  • 4×50mm, 2x50mm guard columns
  • Longer 250mm columns facilitate higher resolution separations of more complex sample matrices
  • Smaller i.d. columns provide higher mass sensitivity, eluent and reagent conservation and lower operating costs

Note: Use with the Dionex IonPac AS4A Eluent Concentrate for simple, accurate eluent preparation.
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text