Columns and Accessories > HPLC Columns > Specialty HPLC Columns > Acclaim Mixed-Mode WAX-1 Columns: A simple solution to difficult separations
 
Specifications  /  Order Info  /  Data SheetsPrinter Friendly
Acclaim Mixed-Mode WAX-1 Columns: A simple solution to difficult separations

Acclaim® Mixed-Mode WAX-1 columns are packed with a new silica based stationary phase that incorporates both hydrophobic and weak anion-exchange properties.  

Separation of different types of molecules including bases, neutrals, and acids, in complicated mixtures within a single chromatographic run on the same column is challenging. The novel column chemistry of the Acclaim Mixed-Mode WAX-1 results in a multimode separation mechanism including hydrophobic, anion-exchange, and ion exclusion interactions. Consequently, retention of basic, neutral, and acidic molecules can be either independently or concurrently adjusted by changing ionic strength, pH, and organic solvent content in the mobile phase.

The Acclaim Mixed-Mode WAX-1 column features:

  • Adjustable selectivity
  • Selectivity orthogonal to reversed phase (RP) columns
  • High capacity and unique selectivity for anionic molecules
  • Simultaneous separation of acidic, basic, and neutral molecules
  • Multimode retention mechanisms: reversed-phase, anion-exchange, and HILIC modes

The Acclaim Mixed-Mode WAX-1 column combines both hydrophobic and anion-exchange characteristics, which facilitates easy-to-adjust selectivity by changing mobile phase ionic strength, pH, or organic content, either independently or concurrently. Because of its unique column chemistry, the Acclaim Mixed-Mode WAX-1 column also provides “complimentary” selectivity to C18 reversed-phase columns.

Acclaim Mixed-Mode WAX-1 Columns: A simple solution to difficult separations  Specifications
Column ChemistryAlkyl amine
Base silicaSpherical, high-purity
Particle size5 µm
Pore size120 Å
Surface area300 m2/g
Order Information
Acclaim Mixed-Mode WAX-1, 5 µm (4.6 x 150 mm)064984
Acclaim Mixed-Mode WAX-1, 5 µm (4.6 x 250 mm)064985
Acclaim Mixed-Mode WAX-1, 5 µm Guard Cartridges (4.3 x 10 mm), 2 Each064986
Acclaim Mixed-Mode WAX-1, 5 µm, 2.1 x 150 mm067084
Acclaim Mixed-Mode WAX-1 Guard, 5µm (2.0 x 10 mm), Set of 2067085
Data Sheets
Acclaim Mixed-Mode WAX-1 Column: Total Control of Selectivity   723K
Acclaim Mixed-Mode WAX-1 Analytical Column Manual   919K
Acclaim 120 Reversed-Phase Columns

The Acclaim® 120 columns are a highly characterized line of LC/MS compatible C18 and C8 phases that have very high surface coverage and very low metal content. These columns provide exceptional performance for a variety of applications in the pharmaceutical, nutraceutical, food, and life science separations areas.

Acclaim Library

A  selection of applications for Acclaim columns.

     