BorateTrap for Optimal Performance During Carbohydrate Analysis

The BorateTrapTM is an in-line trap column, and is recommended for optimal performance during carbohydrate analysis.

  • In-line trap column removes borate contamination for HPAE-PAD.
  • Eliminates peak tailing for mannose, fructose, and sugar alcohols resulting from borate contamination. 

Borate contamination in eluents can cause a significant loss of peak efficiency, especially for mannose, fructose, and reduced monosaccharides. If borate is present in the eluent, it binds both to the anion-exchange column and to the carbohydrate analytes. The carbohydrate-borate complex is less efficiently eluted from the anion-exchanger than is the carbohydrate, resulting in peak tailing, particularly where vicinal cis hydroxyl groups are present, such as for mannose and sugar alcohols. The BorateTrap eliminates peak tailing for mannose, fructose, and reduced monosaccharides, resulting from contamination of the eluent from borate. Therefore, the BorateTrap is highly recommended for optimal performance during carbohydrate analysis.

The BorateTrap is a 4 × 50 mm column placed between the eluent pump and the injection valve to remove borate contamination from eluents used for HPAE-PAD. Because it is placed before the injection valve, it has no effect on the efficiencies or retention times of the carbohydrate analytes. This column is packed with a 20-µm high-capacity resin that has high selectivity for borate. The resin used in the BorateTrap is functionalized with a polyol capable of complexing borate in the presence of hydroxide. Borate is a known contaminant in laboratory water supplies. In chromatography, borate contamination of HPLC eluents may be a result of degrading deionized water systems or as leachate from borosilicate glassware.

BorateTrap for Optimal Performance During Carbohydrate Analysis  Specifications
Contact your local representative for more information.
Order Information
Borate Trap Column047078
Data Sheets
CarboPac MA1 Column for Carbohydrate Alditol and Aldose Analysis Data Sheet   400K
CarboPac PA1 and PA10 Columns for Mono- and Disaccharide Analysis Data Sheet   322K
CarboPac PA20 Column Data Sheet   135K
CarboPac MA1, PA1, PA10, PA100 Analytical Columns Manual   2MB
CarboPac PA20 Analytical Column Manual   2MB
TN 40: Glycoprotein Monosaccharide Analysis Using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (HPAE-PAD)   268K
CarboPac MA1 Carbohydrate Column

The CarboPacTM MA1 is a high-capacity, anion-exchange column designed for the separation of reduced monosaccharides and disaccharides with pulsed amperometric detection

CarboPac PA1 Carbohydrate Column

The CarboPacTM PA1 is a general-purpose column for the analysis of monosaccharides, disaccharides, and linear polysaccharide profiling with direct detection.

CarboPac PA10 Carbohydrate Column

The CarboPacTM PA10 is a specialized column for the high-sensitivity analysis of monosaccharides and disaccharides.

CarboPac PA20 Carbohydrate Column

The CarboPacTM PA20 is a strong anion-exchange column for high-resolution separations of mono- and disaccharides, with no need for derivatization.  

     