Columns and Accessories > Bio Columns > Amino Acid Columns > AminoPac PA10 Column for Amino Acid Analysis by AAA-Direct
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
AminoPac PA10 Column for Amino Acid Analysis by AAA-Direct

The AminoPac® PA10 strong anion-exchange column is a microbore column used for high-resolution separations of free amino acids by AAA-DirectTM.

  • Carbohydrates and amino acids monitored simultaneously
  • >50× more sensitive than ninhydrin-based analyzers; mid-femtomole to low-picomole detection limits
  • Fast and simple analyses of difficult protein samples (e.g., collagen)
  • Compatible with all commonly used hydrolysis procedures
  • Can be configured for on-line analysis

The AminoPac PA10 column is used for high-resolution separations of free amino acids by AAA-DirectAAA-Direct is a technique that eliminates the need for any form of derivatization, and is therefore compatible with on-line monitoring of cell cultures and fermentation broths. Amino sugars and carbohydrates are detected simultaneously with amino acids if they are present in the sample. Additional capabilities include separation and detection of a wide range of sugars, phosphorylated amino acids, and common oxidation products of sulfur-containing amino acids, such as cysteic acid, methionine sulfone, and methionine sulfoxide.

Detection in AAA-Direct is by integrated pulsed amperometric detection (IPAD) and detection limits compare favorably with precolumn derivatization methods. The MDLs range from 110 femtomoles for histidine up to 4.42 pmole for leucine under standard conditions. AAA-Direct is directly compatible with all four of the commonly used protein hydrolysis procedures. The only sample preparation required with AAA-Direct following hydrolysis is filtration and dilution. This preparation is particularly advantageous when using the alkaline hydrolysis procedure since the hydrolysate must be neutralized when using other techniques. Even difficult samples are straightforward by AAA-Direct. Collagen is considered a difficult sample using classical ninhydrin amino acid analysis, because two runs are required at different dilutions as a consequence of the limited dynamic range of the ninhydrin postcolumn detection, and the disparate concentration levels of the amino acids present in collagen hydrolysates. This application is performed in a single run by AAA-Direct.

The AminoPac PA10 column is packed with a hydrophobic, polymeric, pellicular, anion-exchange resin that is stable over the range of pH 0–14. The unique pH stability of the packing material allows the use of eluent compositions that are conducive to anodic oxidation of amino acids at gold electrodes. The AminoPac PA10 column is recommended for use with the AAA-Direct Amino Acid Analyzer and Dionex Sodium Acetate Reagent, allowing direct detection of primary and secondary amino acids by IPAD, with no need for pre- or postcolumn derivatization.

AminoPac PA10 Column for Amino Acid Analysis by AAA-Direct  Specifications
Recommended operating temperature

30 °C

Typical operating conditions

0.25 mL/min gradient
Recommended flow rate: 0.25 mL/min

Mobile phase compatibility

pH 0–14; 100% compatible with common organic solvents. Dionex sodium acetate ionic form eluents only.

Resin composition

8.5-µm-diameter microporous (<10 Å) bead (55% cross-linked) agglomerated with an 80-nm microbead alkyl ammonium functionalized latex (1% cross-linked).

Anion-exchange capacity

60 µeq/column (2 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Dimensions

AminoPac PA10 Analytical Column:
2 × 250 mm

AminoPac PA10 Guard Column:
2 × 50 mm

Maximum operating pressure

4000 psi (27.9 MPa)

Order Information
AminoPac PA10 Analytical Column (2 x 250 mm)055406
AminoPac PA10 Guard Column (2 x 250 mm)055407
Sodium Acetate Salt (Pre-Weighed Reagent), Pkg of 2059326
AAA-Direct Installation, 3 Days059742
AminoPac PA10 (22 x 250 mm)SP5488
AminoPac PA10 (9 x 250 mm)SP5490
AminoPac PA10 Analytical Column (4 x 250 mm)SP5678
AminoPac PA10 Guard Column (4 x 50 mm)SP5680
IonPac ATC-1 Column, 9 x 24 mm, for AAA-DirectSP5802
Data Sheets
AN 130: Identification of a Hydroxylysine-Containing Peptide Using AAA-Direct   189K
AN 142: Determination of Tryptophan Using AAA-Direct   161K
AN 150: Determination of Amino Acids in Cell Cultures and Fermentation Broths   255K
AminoPac PA10 Analytical Column AAA   2MB
AAA Direct System Installation Guide   225K
TN 50: Determination of the Amino Acid Content of Peptides by AAA-Direct   337K
TN 55: Screening of Sample Matrices and Individual Matrix Ingredients for Suitability in AAA-Direct   89K
AN 179: Carbohydrate and Amino Acid Analysis Using 3-D Amperometry   436K
Disposable Gold Electrodes

Disposable gold electrodes are the latest advancement in electrochemical detection, designed to improve both ease of use and electrode-to-electrode reproducibility.

AAA-Direct Certified Sodium Acetate Salt

Dionex AAA-DirectTM grade sodium acetate is preweighed, so the user simply adds water to produce the correct concentration.

Carbohydrate Removal Cartridge

The Carbohydrate Removal Cartridge (CRC) is an in-line sample pretreatment cartridge that removes carbohydrates from your amino acid sample.

     
  Columns and Accessories > Bio Columns > Amino Acid Columns > AminoPac PA10 Column for Amino Acid Analysis by AAA-Direct  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com