Columns and Accessories > IC and RFIC Columns > Trap Columns > IonPac Cation Polisher Columns for Anion Analysis
 
Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac Cation Polisher Columns for Anion Analysis

IonPac®  CP1 Na+ Form and CP2 H+ Form Cation Polisher Columns are designed for removal of metallic contaminants and other cations such as calcium and magnesium from the sample stream while performing anion analysis. The Cation Polisher Columns improve the performance of ion shromatography systems, particularly with phosphate analysis in the presence of metallic contaminants. High levels of metals or cations in samples can be retained on the guard/analytical columns or the suppressor, which can lead to performance issues such as poor peak shapes or poor recoveries for some anions such as phosphate. The Cation Polisher Columns address this potential precipitation issue and aid in extending column and suppressor lifetimes for anion analysis and when the matrix ions contain multivalent cations. 

In some cases the Cation Polisher Columns aid removal of matrix cations during anion analysis with sample preconcentration. The matrix cations can elute species of interest from the concentrator column and lead to poor peak shapes and recovery. Removing the matrix cations using the Cation Polisher Column enables good chromatographic performance.

The CP1 Na+ Form (6 x 16 mm) column is a cation exchange column in the sodium form and packed in a low pressure format. It is specifically designed for autosampler operation. The void volume of this column is approximately 250 µL.

The CP2 H+ Form (9 x 24 mm) column is a higher capacity version in the hydronium form, and has a void volume of approximately 825 µL. The CP2 Polisher Column is recommended for large-volume sample preconcentration applications using an external pump. The Cation Polisher Columns can be regenerated off-line approximately every 2-3 months (depending on the level of contamination and usage).

IonPac Cation Polisher Columns for Anion Analysis  Specifications
Dimensions:

IonPac CP1 Na+ Form Cation Polisher Column:
6 x 16 mm

IonPac CP2 H+ Form Cation Polisher Column:
9 x 24 mm

Mobile Phase Compatibility:

0-100% HPLC solvents.

Substrate Characteristics:

Bead Diameter: 20 µm

Crosslinking (%DVB): 55%

Functional Group Characteristics:

Ion-Exchange Group: Fully functionalized with carboxylic acid.

Hydrophobicity: Very Low

Capacity:

170 µeq (6 x 16 mm)

575 µeq (9 x 24 mm)

Void Volume:

250 µL (6 x 16 mm)

825 µL (9 x 24 mm)

Order Information
IonPac CP1 Na+ Form Cation Polisher Column (6x16 mm)064930
IonPac CP2 H+ Form Cation Polisher Column (9x24 mm)064931
Data Sheets
IonPac Cation Polisher Manual   153K
Concentrator and Trap Columns Data Sheet   408K
     
  Columns and Accessories > IC and RFIC Columns > Trap Columns > IonPac Cation Polisher Columns for Anion Analysis  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com