| | | | IonPac AS20 Anion-Exchange Column |
| The IonPac AS20 hydroxide selective anion-exchange column is specifically designed for trace perchlorate in drinking water. Its high capacity and selectivity allows for the determination of perchlorate in drinking water at the low µg/L level. The AS20 column is the specified column in U.S. EPA Method 314.1 (Confirmatory Method). Recommended hydroxide-selective anion-exchange column for U.S. EPA Method 314.1 (Confirmatory Method) for trace perchlorate in drinking water matrices. High capacity: 310 µeq per column. (4 x 250-mm column). Use the Cryptand C1 Concentrator Column for sample preconcentration. Simplified Reagent-FreeTM IC (RFICTM) operation provided by the RFIC Eluent Generator. Requires only a deionized water source to produce sodium hydroxide eluent. Eluent suppression using the ASRS® ULTRA II provides Reagent-Free IC operation with low backgrounds and enhanced analyte sensitivity. Operate at ambient or elevated temperatures. Column selectivity is optimized for a 30 °C operating temperature to ensure reproducible retention times in all environmental conditions. Compatible with organic solvents to enhance analyte solubility, modify column selectivity, or for effective column clean up.
The IonPac AS20 column is a high-capacity, hydroxide-selective anion-exchange column designed for the determination of trace concentrations of perchlorate in drinking water, surface water, and groundwater matrices. The capacity and selectivity of the AS20 ensures that perchlorate can be quantified at low µg/L concentrations using suppressed conductivity detection even in the presence of very high concentrations of chloride, carbonate, and sulfate. The AS20 column is the column specified in U.S. EPA Method 314.1 (Confirmatory Method) for the determination of trace perchlorate in drinking water. The Cryptand C1 Concentrator Column is the specified concentrator column for sample preconcentration in U.S. EPA Method 314.1. The AS20 column is ideally used with RFIC technology for automatic eluent generation. Use the Anion Self-Regenerating Suppressor (ASRS ULTRA II) with the AS20 column for eluent suppression. | | IonPac AS20 Anion-Exchange Column Specifications | | Maximum Operating Pressure: | 3000 psi | | Mobile Phase Compatibility: | pH 0–14; 0–100% HPLC solvents | | Ion Exchange Group: | Functional Group: Alkanol quaternary ammonium ion | | Column Construction: | PEEK with 10–32 threaded ferrule style end fittings. All components are nonmetallic. | | Functional Group Characteristics: | Ultralow Hydrophobicity | | Dimensions: | IonPac AS20 Analytical Column: 2 × 250 mm | IonPac AG20 Guard Column: 2 × 50 mm | IonPac AS20 Analytical Column: 4 × 250 mm | IonPac AG20 Guard Column: 4 × 50 mm |
| | Capacity: | 77.5 µeq (2 × 250-mm analytical column) | 310 µeq (4 × 250-mm analytical column) | 1.5 µeq* (2 × 50-mm guard column) | 6 µeq* (4 × 50-mm guard column) | *Guards are packed with a low-capacity microporous resin. |
| | Substrate Characteristics: | Bead Diameter and Pore Size: 7.5 µm (2 × 250 and 4 × 250 mm); super macroporous resin (2000 Å) 11 µm (2 × 50 and 4 × 50 mm); microporous resin (<1 Å) | Crosslinking (%DVB): 55% |
|
| | Order Information | | IonPac AS20 Analytical Column (2 x 250 mm) | 063065 | | IonPac AG20 Guard Column (2 x 50 mm) | 063066 | | IonPac AS20 Analytical Column (4 x 250 mm) | 063148 | | IonPac AG20 Guard Column (4 x 50 mm) | 063154 |
| |
|
|  |  | RFC-10 and RFC-30 |  | Want to stop manually preparing eluent and regenerants? Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price. |
| IonPac AS16 Column |  | | The IonPac® AS16 column is designed for polarizable anions and trace perchlorate. |
| Cryptand C1 Column | | The IonPac® Cryptand C1 Concentrator column is the recommended concentrator column for the analysis of trace perchlorate in drinking water. |
| ATC-HC Column |  | The IonPac® ATC-HC Anion Trap Column is a high-capacity, anion-exchange trap column designed for use with the EG40 or EG50 Eluent Generators. |
| ATC-3 Column |  | The IonPac® ATC-3 Anion Trap Column contains a high-capacity, low-efficiency, anion-exchange resin used to remove trace anion contamination from eluents. |
| SRS 300 |  | The Self-Regenerating Suppressor, (SRS® 300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity. |
|
|