Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS11-HC Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS11-HC Anion-Exchange Column

Complex sample matrices such as chemical wastewater effluents and fermentation broth solutions contain a variety of inorganic anions and organic acids. The IonPac® AS11-HC was specifically designed to resolve a large number of inorganic anions and organic acid anions in a single run using a hydroxide gradient. 

  • Use the high-capacity AS11-HC column for organic acids and inorganic anions in complex sample matrices or uncharacterized samples.
  • The AS11-HC column is recommended for monovalent and divalent organic acids.
  • Use the low-capacity AS11 column for the fast analysis of organic acids and inorganic anions in well-characterized samples.
  • Use the ICE-AS1 or ICE-AS6 ion-exclusion columns for organic acid analysis in high-ionic-strength samples.
  • Simplified Reagent-FreeTM IC operation is provided by the EG40 or EG50 Eluent Generator, or the RFC-30 Controller, which requires only a deionized water source to produce potassium hydroxide eluent.

The IonPac AS11-HC is a high-capacity, hydroxide-selective, anion-exchange column with selectivity similar to the AS11 column. The AS11-HC is designed to resolve a large number of inorganic anions and organic acid anions in complex matrices including foods, beverages, fermentation solutions, chemical additives, wastewater, brines, and power plant waters. The high-capacity AS11-HC column allows the injection of more concentrated samples without overloading or peak broadening. The AS11-HC provides improved separation over the AS11 column for monovalent carboxylic acids, including quinate, lactate, acetate, propionate, formate, and butyrate. A wide range of organic acids and inorganic anions can be determined in approximately 40 min using a 1.0–60 mM hydroxide gradient at a controlled temperature of 30 ºC coupled with suppressed conductivity detection. The AS11–HC is recommended for Reagent-Free technology using the EG40 or EG50 Eluent Generators, or the RFC-30 Controller. Use the Anion Self-Regenerating Suppressor (ASRS® ULTRA) with the AS11-HC column.

IonPac AS11-HC Anion-Exchange Column  Specifications
Dimensions

IonPac AS11-HC Analytical Column: 2 × 250 mm and 4 × 250 mm

IonPac AG11-HC Guard Column: 2 × 50 mm and 4 × 50 mm

Maximum operating pressure

4000 psi (27 MPa)

Mobil phase compatibility

pH 0–14; 0–100% HPLC solvents

Substrate characteristics

Bead Diameter: 9.0 µm

Pore Size: 2000 Å

Cross-Linking (%DVB): 55%

Latex characteristics

Functional Group: Alkanol quaternary ammonium ion

Latex Cross-Linking: 6%

Latex Diameter: 70 nm

Hydrophobicity: Medium Low

Capacity

72.5 µeq (2 × 250 mm analytical column)

290 µeq (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac AS11-HC Analytical Column (4 x 250 mm)052960
IonPac AS11-HC Analytical Column (2 x 250 mm)052961
IonPac AG11-HC Guard Column (4 x 50 mm)052962
IonPac AG11-HC Guard Column (2 x 50 mm)052963
Data Sheets
IonPac AS11 and AS11-HC Anion-Exchange Columns Data Sheet   504K
AN 123: The Determination of Inorganic Anions and Organic Acids in Fermentation Broths   300K
TN 46: Determination of Trace Anions in Concentrated Glycolic Acid   192K
TN 44: The Determination of Trace Anions in Concentrated Phosphoric Acid   133K
IonPac AS11-HC Analytical Column Manual   547K
AS11 Column

The AS11 column is recommended for fast profiling of organic acids and inorganic anions in well-characterized samples.

ICE-AS1 Column

The IonPac® ICE-AS1 is recommended for fast analysis of aliphatic organic acids and alcohols in complex or high-ionic-strength samples.

ICE-AS6 Column

The IonPac® ICE-AS6 is recommended for the analysis of aliphatic organic acids and alcohols in complex or high-ionic-strength samples.

CR-TC Continuously Regenerated Trap Columns

Dionex's line of CR-TCs purify the eluent continuously.

SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS11-HC Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com