Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS11 Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS11 Anion-Exchange Column

The IonPac® AS11 was specifically designed for fast, gradient screening of inorganic anions and organic acid anions in simple sample matrices.

  • Use the low-capacity AS11 column for the fast analysis of organic acids and inorganic anions in well-characterized samples.
  • The AS11 is good for highly charged anions, including polyphosphates, polycarboxylates, and polysulfonates.
  • Use the high-capacity AS11-HC column for organic acids and inorganic anions in complex sample matrices or uncharacterized samples.
  • The AS16 and AS20 columns are high-capacity columns and are recommended for hydrophobic anions and highly charged anions.
  • Simplified Reagent-FreeTM  IC operation is provided by Eluent Generators, or the RFC-30 Controller, which requires only a deionized water source to produce potassium hydroxide eluent.

The IonPac AS11 is a low-capacity, hydroxide-selective, anion-exchange column designed for the fast profiling of inorganic anions and organic acid anions in foods, beverages, chemical process solutions, wastewater, brines, and power plant waters. The AS11 column can resolve a large number of inorganic anions and organic acids in approximately 15 min using a 0.2–38 mM hydroxide gradient at a controlled temperature of 30 °C coupled with suppressed conductivity detection. The AS11 is ideal for the determination of organic acids and inorganic anions at simple concentrations or organic acids in well-characterized samples. The AS11 is recommended for use with Reagent-Free systems using Eluent Generation, or the RFC-30 Controller. Use the Anion Self-Regenerating Suppressor (ASRS® ULTRA) with the AS11 column.

IonPac AS11 Anion-Exchange Column  Specifications
Dimensions

IonPac AS11 Analytical Column:
2 × 250 mm and 4 × 250 mm

IonPac AG11 Guard Column:
2 × 50 mm and 4 × 50 mm

Maximum operating pressure

4000 psi (27 MPa)

Mobile phase compatibility

pH 0–14; 0–100% HPLC solvents

Substrate characteristics

Bead Diameter: 13 µm

Pore Size: Microporous, <10 Å

Cross-Linking (%DVB): 55%

Latex characteristics

Functional Group: Alkanol quaternary ammonium ion

Latex Cross-Linking: 6%

Latex Diameter: 85 nm

Hydrophobicity: Very Low

Capacity

11 µeq (2 × 250 mm analytical column)

45 µeq (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac AS11 Analytical Column (4 x 250 mm)044076
IonPac AS11 Analytical Column (2 x 250 mm)044077
IonPac AG11 Guard Column (4 x 50 mm)044078
IonPac AG11 Guard Column (2 x 50 mm)044079
IonPac AS11 Semi-Prep Column (9 x 250 mm)SP2870
IonPac AS11 Semi-Prep Column (22 x 250 mm)SP4430
Data Sheets
IonPac AS11 and AS11-HC Anion-Exchange Columns Data Sheet   504K
AN 123: The Determination of Inorganic Anions and Organic Acids in Fermentation Broths   300K
AU 122: The Determination of Iodide in Brine   69K
AU 140: The Determination of Iodide in Urine   48K
AN 71: Determination of Polyphosphates Using Ion Chromatography with Suppressed Conductivity Detection   57K
AN 113: Determination of Trace Anions in High Purity Waters by High Volume/Direct Injection Ion Chromatography   188K
AN 114: Determination of Trace Anions in High-Purity Waters Using Direct Injection and Two-Step Isocratic Ion Chromatography   148K
AN 107: Ions In Physiological Fluids   133K
AN 37: The Determination of Iodide in Milk Products   119K
IonPac AS11 Analytical Column Manual   413K
AN 116: Quantification of Anions in Pharmaceuticals   96K
AN 104: Analysis of Personal Care Products by Ion Chromatography   76K
AN 25: Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages   166K
TN 46: Determination of Trace Anions in Concentrated Glycolic Acid   192K
AN 37: The Determination of Iodide in Milk Products   119K
AS11-HC Column

The IonPac® AS11-HC is a high-capacity, hydroxide-selective column recommended for the determination of organic acids and inorganic anions in uncharacterized samples.

ICE-AS1 Column

The IonPac® ICE-AS1 is recommended for fast analysis of aliphatic organic acids and alcohols in complex or high-ionic-strength samples.

ICE-AS6 Column

The IonPac® ICE-AS6 is recommended for the analysis of aliphatic organic acids and alcohols in complex or high-ionic-strength samples.

CR-TC Continuously Regenerated Trap Columns

Dionex's line of CR-TCs purify the eluent continuously.

SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS11 Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com