Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS18 Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS18 Anion-Exchange Column

Designed specifically for compliance monitoring of inorganic anions in accordance with U.S. EPA Method 300.0 (A) and 300.1, the IonPac® AS18 represents the culmination of more than 20 years of column development, and is a key part of our award-winning Reagent-FreeTM Ion Chromatography (RFICTM) system—a revolutionary step in ion chromatography that requires only a source of deionized water to produce potassium hydroxide eluent.

  • Recommended hydroxide-selective column for mg/L to µg/L levels of the common inorganic anions in diverse sample matrices
  • Fast isocratic separation of the common inorganic anions in 9 min
  • Hydroxide gradients for inorganic anion and low-molecular-weight organic acids in complex sample matrices
  • Superior retention and quantification of fluoride, acetate, and formate
  • Meets performance requirements specified in U.S. EPA Method 300.0 (A)
  • Ideal alternative, using potassium hydroxide eluents, for AS4A-SC, AS12A, AS14, AS14A, and AS17 anion applications
The IonPac AS18 is designed for the determination of inorganic anions and low-molecular-weight organic acids in a variety of sample matrices, including drinking water, wastewater, foods and beverages, industrial cooling waters, and scrubber solutions. The AS18 column can be used with isocratic hydroxide eluents or hydroxide gradients for the determination of inorganic anions. The capacity and selectivity of the AS18 column provides the flexibility to modify the eluent conditions for optimum separation of the anions of interest. The AS18 has excellent retention of fluoride from the water dip and baseline resolution of fluoride, acetate, and formate. The AS18 column is approved for compliance monitoring of inorganic anions in drinking water and wastewater samples in accordance with U.S. EPA Methods 300.0 and 300.1. The AS18 is recommended for RFIC technology using the EG40 or EG50 Eluent Generators, or the RFC-30 Controller. Use the Anion Self-Regenerating Suppressor (ASRS® ULTRA) or the Anion Atlas® Electrolytic Suppressor (up to 25 µeq/min) with the AS18 column. The AS18 column is an ideal alternative, using potassium hydroxide eluents, for AS4A-SC, AS12A, AS14, AS14A, and AS18 inorganic anion applications.

IonPac AS18 Anion-Exchange Column  Specifications
Dimensions

IonPac AS18 Analytical Column:
2 × 250 mm and 4 × 250 mm

IonPac AG18 Guard Column:
2 × 50 mm and 4 × 50 mm

Maximum operating pressure4000 psi
Mobile phase compatibilitypH 0–14; 0–100% HPLC solvents
Latex characteristics

Functional Group: Alkanol quaternary ammonium ion

Latex Cross-Linking: The effective cross-linking after functionalization is 8%

Latex Diameter: 65 nm

Hydrophobicity: Low

Substrate characteristics

Bead Diameter and Pore Size:

7.5 µm (2 × 250 and 4 × 250 mm); super macroporous resin (2000 Å)

13 µm (2 × 50 and 4 × 50 mm); microporous resin (<10 Å)

Cross-Linking (%DVB): 55%

Capacity

75 µeq (2 × 250 mm analytical column)
2.5 µeq* (2 × 50 mm guard column)

285 µeq (4 × 250 mm analytical column)
10 µeq* (4 × 50 mm guard column)

*Guards are packed with a low-capacity microporous resin.

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac AS18 4 mm Analytical Column (4 x 250 mm)060549
IonPac AG18 4 mm Guard Column (4 x 50 mm)060551
IonPac AS18 2 mm Analytical Column (2 x 250 mm)060553
IonPac AG18 2 mm Guard Column (2 x 50 mm)060555
Data Sheets
IonPac AS18 Anion-Exchange Columns Data Sheet   192K
IonPac AS18 Analytical Column Manual   376K
Ion Standards

The IonPac® ready-to-use ion standards are designed for routine anion or cation determinations.

CR-TC Continuously Regenerated Trap Columns

Dionex's line of CR-TCs purify the eluent continuously.

SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS18 Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com