Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS15 Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS15 Anion-Exchange Column

The semiconductor and power generation industries analyze for trace levels of anions in high-purity water matrices. The IonPac® AS15 column was designed specifically for this application. Its high capacity and selectivity allows for the determination of trace-level concentrations of inorganic anions and low-molecular-weight organic acids in high-purity water matrices.

  • Use the AS15-5µm (3 × 150 mm) column for high efficiency and fast analysis (15 min). The new smaller diameter resin technology provides faster analysis time, reduced eluent consumption, and increased sensitivity.
  • Use the AS15-9µm (2 × 250 and 4 × 250 mm) columns for higher-capacity applications (25-min analysis time).
  • Column selectivity is optimized for a 30 ºC operating temperature to ensure reproducible retention times.
  • Superior retention and resolution is attained of early-eluting anions, including fluoride, glycolate, acetate, and formate.
  • Simplified Reagent-FreeTM IC operation is provided by the EG40 or EG50 Eluent Generators, or the RFC-30 Controller, which requires only a deionized water source to produce potassium hydroxide eluent.
The IonPac AS15 column is a high-capacity, hydroxide-selective, anion-exchange column designed for the determination of trace-level concentrations of inorganic anions and low-molecular-weight organic acids in the high-purity water matrices encountered in the semiconductor and power generation industries. This column is ideal for use with large-loop injections. Use the AC15 concentration column for optimum recovery and precision of ultratrace (ppt) analyses. Use with the EG40 or EG50 Eluent Generator for simplified eluent preparation. Use the Anion Self-Regenerating Suppressor (ASRS® ULTRA) with the AS15 column.

IonPac AS15 Anion-Exchange Column  Specifications
Dimensions

IonPac AS15 Analytical Column:
2 × 250 mm, 3 × 150 mm, and 4 × 250 mm

IonPac AG15 Guard Column:
2 × 50 mm, 3 × 30 mm, and 4 × 50 mm

IonPac AC15 Concentrator Column:
2 × 50 mm and 4 × 50 mm

Maximum operating pressure4000 psi
Mobile phase compatibilitypH 0–14; 0–100% HPLC solvents
Substrate characteristics

Bead Diameter: 5 µm (3 × 150 mm), 9 µm (2 × 250 mm and 4 × 250 mm),
13 µm (AC15)

Pore Size: 100 Å (AS15, AG15), microporous, <10 Å (AC15)

Cross-Linking (%DVB): 55%

Latex characteristics (AC15)

Latex Cross-Linking: 6%

Latex Diameter: 85 nm

Ion-exchange group

Surface-functionalized with alkanol quaternary ammonium ion (AS15, AG15)

Latex-functionalized with alkanol quaternary ammonium ion (AC15)

Functional group characteristics

Medium-high hydrophobic (AS15, AG15)

Very low hydrophobic (AC15)

AC15 void volume

2 × 50 mm: 9 µL

4 × 50 mm: 210 µL

Column constructionPEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.
Capacity

2 × 250 mm analytical column: 56.25 µeq
2 × 50 mm guard column: 11.25 µeq
2 × 50 mm concentrator column: 2.2 µeq

3 × 150 mm analytical column: 70 µeq
3 × 30 mm guard column: 14 µeq

4 × 250 mm analytical column: 225 µeq
4 × 50 mm guard column: 45 µeq
4 × 50 mm concentrator column: 9 µeq

Order Information
IonPac AS15 Analytical Column (4 x 250 mm)053940
IonPac AS15 Analytical Column (2 x 250 mm)053941
IonPac AG15 Guard Column (4 x 50 mm)053942
IonPac AG15 Guard Column (2 x 50 mm)053943
IonPac AS15-5 µm Analytical Column (3x150 mm)057594
IonPac AG15-5 µm Guard Column (3x30 mm)057597
Data Sheets
IonPac AS15 Anion-Exchange Column Data Sheet   200K
AN 137: Determination of Trace Anions in High-Nitrate Matrices by Ion Chromatography   226K
AU 143: Determination of Chloride in Acid Copper Plating Bath   61K
AU 142: Improved Determination of Trace Anions in High Purity Waters by High-Volume Direct Injection with the EG40   96K
IonPac AS15 Analytical Column Manual   717K
AN 179: Carbohydrate and Amino Acid Analysis Using 3-D Amperometry   436K
AC15 Column

The IonPac® AC15 is an anion-exchange concentrator column designed for use with the IonPac AS15 column.

Ion Standards

The IonPac® ready-to-use ion standards are designed for routine anion or cation determinations.

CR-TC Continuously Regenerated Trap Columns

Dionex's line of CR-TCs purify the eluent continuously.

SRS 300

The Self-Regenerating Suppressor, (SRS®  300), is used for electrolytically regenerated suppression of ion chromatography applications requiring high capacity, fast start-up, and sensitivity.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Hydroxide-Selective Anion Columns > IonPac AS15 Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com