Columns and Accessories > IC and RFIC Columns > Cation Columns  > IonPac CS12 Cation-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac CS12 Cation-Exchange Column

The IonPac® CS12 is a high-capacity, cation-exchange column designed for the fast, isocratic separation of lithium, sodium, ammonium, potassium, magnesium, and calcium using methanesulfonic or sulfuric acid eluents in diverse sample matrices. The CS12A column provides improved performance and is the recommended column for inorganic cation analysis.

  • Use the CS12 for fast analysis of the common inorganic anions.
  • The CS12 column can be used for alkanolamines.
  • The CS12A column provides improved performance for fast analysis of inorganic cations.
  • Simplified Reagent-FreeTM IC operation is provided by the EG40 or EG50 Eluent Generator, or the RFC-30 Controller, which requires only a deionized water source to produce methanesulfonic acid eluent.
  • Sample matrices include environmental waters, power plant waters treated with ammonium, morpholine or ethanolamine, chemical additives, chemical process solutions, scrubber solutions, plating baths, and industrial solvents.

The CS12 is designed for fast, isocratic separation with suppressed conductivity detection. The common inorganic cations can easily be determined in diverse sample matrices, including drinking water, power plant waters, soil extracts, acid digests, chemical additives, chemical process solutions, scrubber solutions, and plating baths. Use the CS12A with the EG40 Eluent Generator or EG50 Eluent Generator for simplified methanesulfonic acid eluent preparation. Use the Cation Atlas® Electrolytic Suppressor, CAES®, (up to 25 µeq/column) with the CS12 column.

IonPac CS12 Cation-Exchange Column  Specifications
Dimensions

IonPac CS12 Analytical Column:
2 × 250 mm and 4 × 250 mm

IonPac CG12 Guard Column:
2 × 50 mm and 4 × 50 mm

Maximum operating pressure

4000 psi (27 MPa)

Mobile phase compatibility

Acidic eluents; 0–100% HPLC solvent compatible. Alcohols should be avoided.

Substrate characteristics

Bead Diameter: 8.0 µm

Cross-Linking (%DVB): 55%

Macroporous Dimensions Pore Size: 60 Å

Surface Area: 300 m2/g

Functional group characteristics

Ion-Exchange Group: Carboxylic acid

Surface Characteristics: Hydrophobic

Capacity

0.7 meq (2 × 250 mm analytical column)

2.8 meq (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac CS12 Analytical Column (4 x 250 mm)044001
IonPac CG12 Guard Column (4 x 50 mm)044002
IonPac CS12 Analytical Column (2 x 250 mm)044019
IonPac CG12 Guard Column (2 x 50 mm)044020
Data Sheets
IonPac CS12 Cation Exchange Column Data Sheet   54K
AN 106: Ion Chromatography in the Pharmaceutical Industry   89K
IonPac CS12 Analytical Column Manual   434K
CS12A Column

The IonPac® CS12A is the recommended column for the fast separation of mono- and divalent cations.

Ion Standards

The IonPac® ready-to-use ion standards are designed for routine anion or cation determinations.

AES

The fifth-generation Atlas® Electrolytic Suppressor delivers very low noise with fast start-up and is tailored for use with carbonate and MSA eluents. It can also be used with hydroxide and even sulfuric acid.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Cation Columns  > IonPac CS12 Cation-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map