Columns and Accessories > IC and RFIC Columns > Cation Columns  > IonPac CS12A Cation-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac CS12A Cation-Exchange Column

The IonPac® CS12A is a high-capacity, cation-exchange column recommended for the fast, isocratic separation of lithium, sodium, ammonium, potassium, magnesium, and calcium using methanesulfonic or sulfuric acid eluents in diverse sample matrices.

  • Use the CS12A-5µm (3 × 150 mm) column for high efficiency and fast analysis (9 min). The new smaller-diameter resin technology provides faster analysis time, reduced eluent consumption, and increased sensitivity.
  • The CS12A-8µm (2 × 250 mm and 4 × 250 mm) columns are recommended for inorganic cations in complex sample matrices (15-min analysis time).
  • Use the CS12A 2- and 4-mm columns for disparate concentration ratios (up to 1:1000) of sodium and ammonium.
  • The CS12A-MS (2 × 100 mm) is an IC-MS screening column for fast elution and low flow rates required for interfacing with IC-MS detectors.
  • The CS12A column is recommended for manganese and morpholine.
  • Simplified Reagent-FreeTM IC operation is provided by the EG40 or EG50 Eluent Generator, or the RFC-30 Controller, which requires only a deionized water source to produce methanesulfonic acid eluent.
  • Sample matrices include environmental waters, power plant waters treated with ammonium, morpholine or ethanolamine, chemical additives, chemical process solutions, scrubber solutions, plating baths, and industrial solvents.
The high-capacity, cation-exchange CS12A is designed for the fast, isocratic separation with suppressed conductivity detection. The common inorganic cations in diverse sample matrices include drinking water, power plant waters, soil extracts, acid digests, chemical additives, chemical process solutions, scrubber solutions, and plating baths. The CS12A column is designed to be used in most CS12 applications. Use the CS12A with the EG40 or EG50 Eluent Generator for simplified methanesulfonic acid eluent preparation. Use the Cation Atlas® Electrolytic Suppressor, CAES®, (up to 25 µeq/column) with the CS12A column.

IonPac CS12A Cation-Exchange Column  Specifications
Dimensions

IonPac CS12A Analytical Column:
2 × 250 mm, 3 × 150 mm, and 4 × 250 mm

IonPac CG12A Guard Column:
2 × 50 mm, 3 × 30 mm, and 4 × 50 mm

Maximum operating pressure

4000 psi (27 MPa)

Mobile phase compatibility

Acidic eluents; 0–100% acetonitrile. Alcohols should be avoided.

Substrate characteristics

Bead Diameter: 8 µm (2 and 4 mm), 5 µm (3 mm)

Cross-Linking (%DVB): 55%

Functional group characteristics

Ion-Exchange Groups: Grafted carboxylic acid and phosphonic acid

Surface Characteristics: Medium hydrophilic

Capacity

700 µeq (2 × 250 mm analytical column)

940 µeq (3 × 150 mm analytical column)

2800 µeq (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac CS12A Analytical Column (4 x 250 mm)046073
IonPac CG12A Guard Column (4 x 50 mm)046074
IonPac CS12A Analytical Column (2 x 250 mm)046075
IonPac CG12A Guard Column (2 x 50 mm)046076
IonPac CG12A-5 µm Guard Column (3 x 30 mm)057184
IonPac CS12A-5 µm Analytical Column (3 x 150 mm)057185
IonPac CS12A-MS (2 x 100 mm) Column059960
Data Sheets
IonPac CS12A Cation-Exchange Column Data Sheet   343K
AN 120: Determination of Calcium and Magnesium in Brine   84K
AN 107: Ions In Physiological Fluids   133K
AN 106: Ion Chromatography in the Pharmaceutical Industry   89K
AN 124: Determination of Choline in Dry Milk and Infant Formula   78K
AU 137: Determination of Trace Lithium in Industrial Process Waters   58K
IonPac CS12A Analytical Column Manual   723K
AES

The fifth-generation Atlas® Electrolytic Suppressor delivers very low noise with fast start-up and is tailored for use with carbonate and MSA eluents. It can also be used with hydroxide and even sulfuric acid.

Ion Standards

The IonPac® ready-to-use ion standards are designed for routine anion or cation determinations.

RFC-10 and RFC-30

Want to stop manually preparing eluent and regenerants?

Reagent-FreeTM IC with Eluent Generation (RFIC-EGTM ) systems reduce errors and provide consistency in your results, all by just adding water. The RFC-30 allows users to upgrade existing systems to RFIC-EG systems at a reasonable price.

     
  Columns and Accessories > IC and RFIC Columns > Cation Columns  > IonPac CS12A Cation-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map