Columns and Accessories > IC and RFIC Columns > Carbonate-Based Anion Columns > IonPac AS9-SC Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS9-SC Anion-Exchange Column

The IonPac® AS9-SC anion-exchange column is designed for fast analysis of oxyhalides and inorganic anions in environmental waters. This column is specified in U.S. EPA Method 300.0 (B). The high-capacity AS9-HC column is the recommended column for trace bromate in drinking water.

  • Use the AS9-SC column for fast analysis of oxyhalides and inorganic anions at similar concentrations.
  • Use the high-capacity AS9-HC column for trace bromate in ozonated drinking water.

The IonPac AS9-SC (solvent compatible) is a low-capacity, carbonate-based, anion-exchange column designed for the fast, isocratic separation of oxyhalides and inorganic anions, including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate in drinking water, wastewater, groundwater, and other diverse sample matrices. The common inorganic anions and oxyhalides can be determined in less than 10 min using an isocratic carbonate/bicarbonate eluent coupled with suppressed conductivity detection. The AS9-SC is specified in validated methods such as U.S. EPA Method 300.0 (B) and meets or exceeds the performance requirements of this method. Use the Atlas® Anion Electrolytic Suppressor (AAES®) with the AS9-SC column.

IonPac AS9-SC Anion-Exchange Column  Specifications
Dimensions

IonPac AS9-SC Analytical Column:
4 × 250 mm

IonPac AG9-SC Guard Column:
4 × 50 mm

Maximum operating pressure

4000 psi

Mobile phase compatibility

pH 2–11; 0–100% HPLC solvents

Substrate characteristics

Bead Diameter: 13.0 µm

Cross-Linking (%DVB): 55%

Latex characteristics

Functional Group: Alkyl quaternary ammonium ion

Latex Cross-Linking: 20%

Latex Diameter: 110 nm

Hydrophobicity: Medium

Capacity

30–35 µeq (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
IonPac AS9-SC Analytical Column (4 x 250 mm)043185
IonPac AG9-SC Guard Column (4 x 50 mm)043186
Data Sheets
IonPac AS9-SC and AS9-HC Anion-Exchange Columns Data Sheet   437K
AN 101: Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography   66K
AN 93: Determination of Trace Anions in Concentrated Bases Using AutoNeutralization Pretreatment/Ion Chromatography   1MB
IonPac AS9-SC Analytical Column Manual   725K
AS9-HC Column
The IonPac® AS9-HC is recommended for inorganic anions and oxyhalides, and trace bromate in drinking water.
AES

The fifth-generation Atlas® Electrolytic Suppressor delivers very low noise with fast start-up and is tailored for use with carbonate and MSA eluents. It can also be used with hydroxide and even sulfuric acid.

Eluent Concentrates

The IonPac® eluent concentrates are available for anion and cation determinations. The eluent concentrates are recommended for fast, reliable eluent preparation.

     
  Columns and Accessories > IC and RFIC Columns > Carbonate-Based Anion Columns > IonPac AS9-SC Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map
© 2008 Dionex Corporation. All rights reserved. www.dionex.com