Columns and Accessories > IC and RFIC Columns > Carbonate-Based Anion Columns > IonPac AS9-HC Anion-Exchange Column
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
IonPac AS9-HC Anion-Exchange Column

The IonPac® AS9-HC anion-exchange column is specifically designed for trace bromate in drinking water. This column's high capacity and selectivity allow for the determination of bromate in drinking water at the low-µg/L level. The AS9-HC is the specified column for U.S EPA Method 300.1 and 317.0.

  • Use the high-capacity AS9-HC column for the analysis of oxyhalides and inorganic anions in complex sample matrices.
  • The AS9-HC provides a simple, isocratic method for trace bromate (5 µg/L) in ozonated drinking water matrices.
  • The high-capacity AS9-HC column is ideal for difficult applications, such as trace nitrite in complex sample matrices including meat and milk products, fertilizers, soil extracts, and wastewater.
  • The AS9-HC provides improved separation of bromate/chloride, chloride/nitrite, and chlorate/nitrate analyte pairs.
The IonPac AS9-HC is a high-capacity, carbonate-based, anion-exchange column with selectivity similar to the AS9-SC column. The AS9-HC column is also designed for the analysis of oxyhalides and inorganic anions, including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate. But this column has higher capacity and provides improved separation for trace bromate in drinking water matrices using an isocratic carbonate eluent and a large-loop injection. The AS9-HC also offers improved retention of fluoride out of the water dip. Increased retention time (approximately 22 min) is due to the high capacity (190 µeq for 4 × 250 mm) of the column. The AS9-HC is specified in validated methods such as U.S. EPA Method 300.1 and 317.0 and meets or exceeds the performance requirements of these methods. Use the Atlas® Anion Electrolytic Suppressor (AAES®) with the AS9-HC column.

IonPac AS9-HC Anion-Exchange Column  Specifications
Dimensions

IonPac AS9-HC Analytical Column:
2 × 250 and 4 × 250 mm  

IonPac AG9-HC Guard Column:
2 × 50 mm and 4 × 50 mm

Mobile Phase CompatibilitypH 0–12; 0–100% HPLC solvents
Substrate Characteristics

Bead Diameter: 9.0 µm 

Pore Size: 2000 Å 

Cross-Linking (%DVB): 55%

Latex Characteristics

Functional Group: Alkyl/alkanol quaternary ammonium ion 

Latex Cross-Linking: 15% 

Latex Diameter: 90 nm 

Hydrophobicity: Medium-Low

Maximum Operating Pressure4000 psi
Capacity

47.5 µeq (2 × 250 mm analytical column) 

190 µeq (4 × 250 mm analytical column)

Column ConstructionPEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.
Order Information
IonPac AS9-HC Analytical Column (4 x 250 mm)051786
IonPac AG9-HC Guard Column (4 x 50 mm)051791
IonPac AS9-HC Analytical Column (2 x 250 mm)052244
IonPac AG9-HC Guard Column (2 x 50 mm)052248
Data Sheets
IonPac AS9-SC and AS9-HC Anion-Exchange Columns Data Sheet   437K
AN 135: Determination of Inorganic Anions in Wastewater by Ion Chromatography   132K
AN 136: Determination of Inorganic Oxyhalide Disinfection Byproduct Anions and Bromide in Drinking Water Using Ion Chromatography with the Addition of a Postcolumn Reagent for Trace Bromate Analysis   628K
AN 85: Determination of Trace Anions in Organic Solvents   149K
AN 81: Ion Chromatographic Determination of Oxyhalides and Bromide at Trace Level Concentrations in Drinking Water Using Direct Injection   92K
TN 46: Determination of Trace Anions in Concentrated Glycolic Acid   192K
TN 45: Determination of Trace Anions in Concentrated Hydrofluoric Acid   226K
IonPac AS9-HC Analytical Column Manual   365K
AS9-SC Column

The IonPac® AS9-SC is recommended for fast analysis of inorganic anions and oxyhalides. This column is specified in U.S. EPA Method 300.0 (B).

Eluent Concentrates

The IonPac® eluent concentrates are available for anion and cation determinations. The eluent concentrates are recommended for fast, reliable eluent preparation.

AES

The fifth-generation Atlas® Electrolytic Suppressor delivers very low noise with fast start-up and is tailored for use with carbonate and MSA eluents. It can also be used with hydroxide and even sulfuric acid.

     
  Columns and Accessories > IC and RFIC Columns > Carbonate-Based Anion Columns > IonPac AS9-HC Anion-Exchange Column  
 
Order Literature   Privacy   Feedback   Terms of Use   Trademarks   Site Map