Columns and Accessories > Bio Columns > Carbohydrate Columns > CarboPac PA100 Column for Oligosaccharide Analysis
 
Chromatograms /  Specifications  /  Order Info  /  Data SheetsPrinter Friendly
CarboPac PA100 Column for Oligosaccharide Analysis

With the CarboPacTM PA100, you can have all the details, without the fuss. With no time-consuming derivatization, you can separate complex mixtures of neutral and charged oligosaccharides based on size, charge, degree of branching, anomericity, and linkage isomerism.

  • Separation of closely related oligosaccharides, even isomers, at picomole levels
  • Separation of neutral and charged oligosaccharides in the same run
  • No sample derivatization required for detection
  • The Carbohydrate Membrane Desalter (CMDTM) can be used on-line prior to fraction collection

Characterization of oligosaccharides released from therapeutic glycoproteins is an important task for the biotechnology and pharmaceutical industries. Differences in glycoconjugate-derived oligosaccharides can be as subtle as differences in branching, linkage isomerism, and anomericity. These oligosaccharides can be challenging to separate by other methods, but are easily resolved by the CarboPac PA100. The CarboPac PA100 provides the flexibility to separate oligosaccharides into broad classes depending upon the degree of sialylation, while maintaining the resolution needed for routine analysis of these oligosaccharides based on linkage isomerism. Detection of these compounds at low-picomole levels has been optimized using pulsed amperometric detection (PAD). No sample derivatization is needed for detection. For researchers wishing to collect and further analyze the carbohydrate samples, the CMD may be used to desalt and reduce the pH of the samples following HPAE-PAD.

Oligosaccharides are also routinely determined in food and beverage products for a variety of purposes, such as quality control, verifying food labeling claims, establishing product authenticity, and monitoring fermentation processes. The CarboPac PA100 is an ideal column for detecting adulteration in natural fruit juices, or simply monitoring the levels of fermentable and nonfermentable sugars in beer production based on oligosaccharide profiling.

The CarboPac PA100 column is a high-resolution, strong, anion-exchange column developed for enhanced chromatography of oligosaccharides. The entire manufacturing process (including resin synthesis, amination, and packing of the columns) is carefully controlled to ensure that every CarboPac PA100 delivers reproducible performance.  CarboPac PA100 columns are tested with two isomers of N-acetylneuraminosyl-D-lactose to ensure lot-to-lot consistency. 

CarboPac PA100 Column for Oligosaccharide Analysis  Specifications
Dimensions

CarboPac PA100 Analytical Column:
4 × 250 mm

CarboPac PA100 Guard Column:
4 × 50 mm

CarboPac PA100 Microbore Column:
2 × 250 mm

CarboPac PA100 Microbore Guard Column:
2 × 50 mm

CarboPac PA100 Semipreparative Column:
9 × 250 mm

CarboPac PA100 Semipreparative Column:
22 × 250 mm

Maximum operating pressure

4000 psi (27.9 MPa)

Temperature range

4–60 °C

Recommended operating temperature: ambient

Typical operating conditions

2400 psi at 1.0 mL/min (analytical and guard columns)

Recommended flow rate: 1.0 mL/min

Mobile phase compatibility

pH 0–14; 100% compatible with common organic solvents. Ionic form eluents: sodium acetate and sodium hydroxide only.

Resin composition

8.5-µm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linking) agglomerated with 275-nm MicroBeadTM quaternary amine functionalized latex (6% cross-linked).

Anion-exchange capacity

Approximately 90 µeq/column (4 × 250 mm analytical column)

Column construction

PEEK with 10-32 threaded ferrule-style end fittings. All components are nonmetallic.

Order Information
CarboPac PA100 Guard Column (4 x 50 mm)043054
CarboPac PA100 Analytical Column (4 x 250 mm)043055
CarboPac PA100 Analytical Column (2 x 250 mm)057182
CarboPac PA100 Guard Column (2 x 50 mm)057183
CarboPac PA100 Column (9 x 250 mm)SP2089
CarboPac PA100 Column (22 x 250 mm)SP2667
Data Sheets
CarboPac PA100 Column for Oligosaccharide Analysis Data Sheet   381K
CarboPac MA1, PA1, PA10, PA100 Analytical Columns Manual   2MB
AN 46: Ion Chromatography: A Versatile Technique for the Analysis of Beer   170K
AN 67: Determination of Plant-Derived Neutral Oligo- and Polysaccharides   432K
AN 82: Analysis of Fruit Juice Adulterated with Medium Invert Sugar from Beets   433K
AN 105: Glycosylation Analysis of Human Serum Transferrin Glycoforms Using Pellicular Anion-Exchange Chromatography   312K
TN 20: Analysis of Carbohydrates by High Performance Anion Exchange Chromatography with Pulsed Amperometric Detection (HPAE-PAD)   350K
TN 30: Monosaccharide and Oligosaccharide Analysis of Glycoproteins Electrotransferred onto Polyvinylidene Fluoride (PVDF) Membranes   1MB
TN 36: Analysis of Exoglycosidase Digestions of N-Linked Oligosaccharides Using HPAE-PAD   181K
TN 42: Glycoprotein Oligosaccharide Analysis Using High-Performance Anion-Exchange Chromatography   264K
CMD I

The Dionex Carbohydrate Membrane Desalter (CMDTM I) is an on-line device for users of HPAE-PAD who wish to collect and further analyze carbohydrate samples.

CarboPac PA1 Carbohydrate Column

The CarboPacTM PA1 is a general-purpose column for the analysis of monosaccharides, disaccharides, and linear polysaccharide profiling with direct detection.

CarboPac PA200 for Oligosaccharide Analysis

The CarboPacTM PA200 is a polymeric anion-exchange oligosaccharide column, for high-resolution separations of oligosaccharides. This column is particularly well suited to the characterization of glycoprotein oligosaccharides, as well as complex carbohydrates found in dietary fiber.

     
  Columns and Accessories > Bio Columns > Carbohydrate Columns > CarboPac PA100 Column for Oligosaccharide Analysis  
 