| | | | ICS Series Variable Wavelength Detector |
| Get the benefits of performance and versatility of the ICS series Variable Wavelength Detector through the following unique features: - High signal-to-noise ratio for maximum sensitivity
- Broad wavelength range from 190 to 900 nm
- Low noise and high light intensity over the full spectral range by using deuterium and tungsten lamps
- Full control and data collection through Chromeleon® 6 software
- USB-based digital data collection for simple installation
- Data collection rates up to 100 Hz
- Built-in holmium oxide filter for easy verification of wavelength accuracy
- Low baseline drift for reliable results
- Excellent resolution that yields high linearity
- Integrated low backpressure flow cell heat exchanger for thermal stability
- Lamp lifetime monitor to prevent downtime
- Multiple wavelength monitoring; up to four different wavelengths simultaneously
| | | ICS Series Variable Wavelength Detector Specifications | | Noise | Typically <±2.5 x µAU at 254 nm | | Drift | 0.1 mAU/hr at 254 nm | | Wavelength accuracy | ±1 nm | | Wavelength Bandwidth | 6 nm at 254 nm | | Linearity | Up to 2.5 AU | | Data Collection Rate | Up to 100 Hz (Multiple wavelength version) Up to 10 Hz (Single wavelength version) | | Flow Cell | PEEK 11 µL volume, 10 mm path length | | Lamps | Tungsten and deuterium | | Analog outputs | Two: Absorbance, 20-bit resolution, 0–1 Volt and 0–10 Volt. | | Dimensions (h x w x d) | 15.2 × 44.4 × 50.3 cm (6.0 × 17.5 × 20 in.) | | Physical specifications | Power Requirements: 85–265 V ac, 47–63 Hz (autosensing) Operating Temp. Range: 10–35 °C (50–95 °F) Operating Humidity Range: 5–80% relative, noncondensing |
| | Order Information | | Call 1-800-DIONEX-0 (zero) for order information. |
| |
|
|  |  | Award-Winning ICS-3000 RFIC System | The ICS-3000 Reagent-Free™ IC (RFIC™) system has won Five Awards including Editors' Choice Silver Award as one of the best new products at Pittcon '05, Two Gold awards from Instrument Business Outlook. The ICS-3000 allows chemists to save time, labor, and operating cost while increasing the productivity and reproducibility of ion analysis for any application. |
| AS Autosampler | | The AS Autosampler delivers high precision, reliability, ruggedness, and ease of use. This autosampler is compatible with the ICS-3000, ICS-2000, ICS-1500, ICS-1000 and ICS-900 IC systems. |
| SP and DP Pumps | The ICS-3000 Single and Dual Pumps deliver superior performance in any application. |
| EG Eluent Generator | The ICS-3000 EG Eluent Generator allows you to enjoy the benefits of RFICTM systems. |
| Thermal Compartment | The ICS-3000 TC Thermal Compartment offers precise temperature control from 5 to 85 °C. |
| Conductivity Detector | With integrated design and plug-and-play capability, the ICS-3000 CD conductivity detector features ease of use and optimal performance. |
| Electrochemical Detector | New, innovative ED electrochemical detection capabilities improve and expand applications: multiple waveforms in a single run, postrun 3-D data integration optimization, and a new cell design for greater consistency and ease of use. |
|
|