| | | | Mass Spectrometer |
| The MSQTM Plus Mass Spectrometer can be used in a wide range of applications and methodologies in both HPLC and IC. Only 12 in. wide, the MSQ Plus is by far the most compact mass spectrometer on the market today and offers outstanding performance and functionality. The MSQ Plus features a high-sensitivity, self-cleaning ESI/APCI ionization source that requires no mechanical adjustment or electrostatic focusing for sample optimization. The compact triple orthogonal source design is optimized for a wide range of flow rates and can be used with a wide range of chromatographic buffers. It is designed for laboratories that need universal detection and characterization of analytes in the 17–2000 m/z range. - New M PathTM triple orthogonal source technology virtually eliminates neutral noise and background
- Unique FastLocTM probes provide simple and rapid mode changes
- All features of the MSQ Plus are fully supported in the Chromeleon® Chromatography Management software
- Full scan and Selected Ion Monitoring (SIM) allow for rapid screen and target compound analysis
- Precision-engineered quadrupole analyzer maximizes resolution and provides high stability and minimal drift
- Enhanced Low-Mass Option (ELMO) for analytes below 60 m/z
- All new Ion BrightTM detector system eliminates neutral noise, extending the dynamic range
- The MSQ Plus features a self-contained reference inlet system for tuning and calibration.
- Advanced autotuning wizard includes full system optimization and mass scale calibration.
| | | Mass Spectrometer Specifications | | Power Requirements | 230 V ac 13A power outlets (for rotary pump and MSQ) 230 or 115 V ac (as required) for PC and monitor and additional hardware | | Gas Requirements | MSQ requires a supply of high-purity (>99%) nitrogen capable of supplying 600 L/h at 75 psi (5 bar) | | Dimensions (h x w x d) and Weight | 530 × 300 × 710 mm (21 × 12 × 28 in.) 60 kg (132 lb) | | Ionization Modes (supplied as standard) | Electrospray (ESI) Atmospheric Pressure Chemical Ionization (APCI) | | Range | 17–2000 m/z | | Sensitivity | Sensitivity specifications are performed using loop injections at a flow of 1 mL/min in SIM mode. Noise is defined as RMS after appropriate smoothing. Positive ion ESI—50 pg injection (10 μL × 5 pg/μL) of erythromycin: 1000:1 S/N Negative ion ESI—20 pg loop injection (10 μL × 2 pg/μL) of p-nitrophenol: 500:1 S/N Positive ion APCI—50 pg injection (10 μL × 5 pg/μL) of erythromycin: 200:1 S/N Negative ion APCI—20 pg injection (10 μL × 2 pg/μL) of p-nitrophenol: 50:1 S/N |
| | Order Information | | MSQ Plus Mass Spectrometric Detector | 063116 | | Consumables Supplies for MSQ | 060046 | | Nitrogen Gas Generator | 068126 | | AXP-MS Auxiliary Pump | 060684 | | Kit for Analyzer Maintenance | 061494 | | Kit for API Probe Maintenance | 061495 | | Server Option: MS Control | 060726 | | Perchlorate O-18 Internal Standard, 1 mg/L, 10 mL | 062923 |
| |
|